Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus.
Descripción del Articulo
Introduction: Mini screws are devices used to optimize anchorage in orthodontics, and are fixed in the bone structure. Case of report: We present the case of a patient who came to the oral and maxillofacial surgery office due to the accidental introduction of a mini orthodontic screw into the maxill...
Autores: | , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2024 |
Institución: | Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo |
Repositorio: | Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo |
Lenguaje: | español |
OAI Identifier: | oai:cmhnaaa_ojs_cmhnaaa.cmhnaaa.org.pe:article/2337 |
Enlace del recurso: | https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/2337 |
Nivel de acceso: | acceso abierto |
Materia: | Ortodoncia Complicaciones Anclaje en ortodoncia Láser Orthodontics Complications Orthodontic anchorage Laser |
id |
REVCMH_4eec68d53aa9aac2b3f30b9301ac9657 |
---|---|
oai_identifier_str |
oai:cmhnaaa_ojs_cmhnaaa.cmhnaaa.org.pe:article/2337 |
network_acronym_str |
REVCMH |
network_name_str |
Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo |
repository_id_str |
|
spelling |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus.Fotobiomodulación para el manejo del dolor y parestesia posterior a la extracción quirúrgica de mini tornillo ortodóntico en el seno maxilar.Herrera-Plasencia , Paul Martín Bermeo Flores, Mary LissetCastillo Bayona, Evelin Anais De La Puente Dongo , José Luis OrtodonciaComplicacionesAnclaje en ortodonciaLáserOrthodonticsComplicationsOrthodontic anchorageLaserIntroduction: Mini screws are devices used to optimize anchorage in orthodontics, and are fixed in the bone structure. Case of report: We present the case of a patient who came to the oral and maxillofacial surgery office due to the accidental introduction of a mini orthodontic screw into the maxillary sinus; a tomographic evaluation was requested, determining the thickening of the Schneider membrane and the presence of the foreign body inside it. The Caldwell-Luc surgical technique was performed and the mini screw was located and removed. Subsequent complications were pain on touch and paresthesia; a laser therapy with photobiomodulation was performed, and both pain and paresthesia were resolved. Conclusion: One year after surgery, the patient was asymptomatic and without paresthesia, the control tomography verified absence of Schneider's membrane thickening and permeable anatomical repairs of the left maxillary sinus.Introducción: Los mini tornillos son dispositivos que se utilizan para optimizar el anclaje en ortodoncia, y son fijados en la estructura ósea. Reporte de caso: Se presenta el caso de una paciente que recurre a la consulta de cirugía oral y maxilofacial por introducción accidental de un mini tornillo ortodóntico al seno maxilar; se le solicitó una evaluación tomográfica, determinándose el engrosamiento de la membrana de schneider y la presencia del cuerpo extraño en su interior. Se le realizó la técnica quirúrgica de Caldwll-Luc y se pudo ubicar y extraer el mini tornillo. Las complicaciones posteriores fueron dolor a la palpación y parestesia; una terapia de laser con fotobiomodulación fue realizada, y tanto el dolor como la parestesia fueron resueltas. Conclusión: Al año de la cirugía, la paciente se encontraba asintomática y sin parestesia, la tomografía de control verificó ausencia de engrosamiento de la membrana de Schneider y reparos anatómicos del seno maxilar izquierdo permeables.Cuerpo Médico del Hospital Nacional Almanzor Aguinaga Asenjo2024-05-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/233710.35434/rcmhnaaa.2024.171.2337Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 17 No. 1 (2024): Early Publication; e2337Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 17 Núm. 1 (2024): Rev. Cuerpo Med. HNAAA, Enero - Marzo; e23372227-47312225-510910.35434/rcmhnaaa.2024.171reponame:Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjoinstname:Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjoinstacron:HNAAAspahttps://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/2337/922Derechos de autor 2024 Paul Martín Herrera-Plasencia , Mary Lisset Bermeo Flores, Evelin Anais Castillo Bayona, José Luis De La Puente Dongo https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:cmhnaaa_ojs_cmhnaaa.cmhnaaa.org.pe:article/23372025-05-14T10:42:36Z |
dc.title.none.fl_str_mv |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. Fotobiomodulación para el manejo del dolor y parestesia posterior a la extracción quirúrgica de mini tornillo ortodóntico en el seno maxilar. |
title |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. |
spellingShingle |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. Herrera-Plasencia , Paul Martín Ortodoncia Complicaciones Anclaje en ortodoncia Láser Orthodontics Complications Orthodontic anchorage Laser |
title_short |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. |
title_full |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. |
title_fullStr |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. |
title_full_unstemmed |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. |
title_sort |
Photobiomodulation for the management of pain and paresthesia following surgical removal of mini orthodontic screw in the maxillary sinus. |
dc.creator.none.fl_str_mv |
Herrera-Plasencia , Paul Martín Bermeo Flores, Mary Lisset Castillo Bayona, Evelin Anais De La Puente Dongo , José Luis |
author |
Herrera-Plasencia , Paul Martín |
author_facet |
Herrera-Plasencia , Paul Martín Bermeo Flores, Mary Lisset Castillo Bayona, Evelin Anais De La Puente Dongo , José Luis |
author_role |
author |
author2 |
Bermeo Flores, Mary Lisset Castillo Bayona, Evelin Anais De La Puente Dongo , José Luis |
author2_role |
author author author |
dc.subject.none.fl_str_mv |
Ortodoncia Complicaciones Anclaje en ortodoncia Láser Orthodontics Complications Orthodontic anchorage Laser |
topic |
Ortodoncia Complicaciones Anclaje en ortodoncia Láser Orthodontics Complications Orthodontic anchorage Laser |
description |
Introduction: Mini screws are devices used to optimize anchorage in orthodontics, and are fixed in the bone structure. Case of report: We present the case of a patient who came to the oral and maxillofacial surgery office due to the accidental introduction of a mini orthodontic screw into the maxillary sinus; a tomographic evaluation was requested, determining the thickening of the Schneider membrane and the presence of the foreign body inside it. The Caldwell-Luc surgical technique was performed and the mini screw was located and removed. Subsequent complications were pain on touch and paresthesia; a laser therapy with photobiomodulation was performed, and both pain and paresthesia were resolved. Conclusion: One year after surgery, the patient was asymptomatic and without paresthesia, the control tomography verified absence of Schneider's membrane thickening and permeable anatomical repairs of the left maxillary sinus. |
publishDate |
2024 |
dc.date.none.fl_str_mv |
2024-05-02 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/2337 10.35434/rcmhnaaa.2024.171.2337 |
url |
https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/2337 |
identifier_str_mv |
10.35434/rcmhnaaa.2024.171.2337 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://cmhnaaa.org.pe/ojs/index.php/rcmhnaaa/article/view/2337/922 |
dc.rights.none.fl_str_mv |
https://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Cuerpo Médico del Hospital Nacional Almanzor Aguinaga Asenjo |
publisher.none.fl_str_mv |
Cuerpo Médico del Hospital Nacional Almanzor Aguinaga Asenjo |
dc.source.none.fl_str_mv |
Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 17 No. 1 (2024): Early Publication; e2337 Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo; Vol. 17 Núm. 1 (2024): Rev. Cuerpo Med. HNAAA, Enero - Marzo; e2337 2227-4731 2225-5109 10.35434/rcmhnaaa.2024.171 reponame:Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo instname:Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo instacron:HNAAA |
instname_str |
Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo |
instacron_str |
HNAAA |
institution |
HNAAA |
reponame_str |
Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo |
collection |
Revista del Cuerpo Médico Hospital Nacional Almanzor Aguinaga Asenjo |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1843263933755949056 |
score |
12.672554 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).