Backscatter coefficient estimation using highly focused ultrasound transducers
Descripción del Articulo
The backscatter coefficient (BSC) is an intrinsic property that quantifies the amount of energy that is reflected by a material as function of the ultrasound wave frequency. BSCs have been proposed for decades for tissue characterization, along with quantitative ultrasound (QUS) parameters derived f...
| Autor: | |
|---|---|
| Formato: | tesis de maestría |
| Fecha de Publicación: | 2013 |
| Institución: | Pontificia Universidad Católica del Perú |
| Repositorio: | PUCP-Tesis |
| Lenguaje: | inglés |
| OAI Identifier: | oai:tesis.pucp.edu.pe:20.500.12404/5339 |
| Enlace del recurso: | http://hdl.handle.net/20.500.12404/5339 |
| Nivel de acceso: | acceso abierto |
| Materia: | Métodos de simulación Transductores Ultrasonido https://purl.org/pe-repo/ocde/ford#2.02.05 |
| id |
PUCP_9244766ba9b85375d486f0b1ea0cf72b |
|---|---|
| oai_identifier_str |
oai:tesis.pucp.edu.pe:20.500.12404/5339 |
| network_acronym_str |
PUCP |
| network_name_str |
PUCP-Tesis |
| repository_id_str |
. |
| dc.title.es_ES.fl_str_mv |
Backscatter coefficient estimation using highly focused ultrasound transducers |
| title |
Backscatter coefficient estimation using highly focused ultrasound transducers |
| spellingShingle |
Backscatter coefficient estimation using highly focused ultrasound transducers Panizo Ríos, Diego Métodos de simulación Transductores Ultrasonido https://purl.org/pe-repo/ocde/ford#2.02.05 |
| title_short |
Backscatter coefficient estimation using highly focused ultrasound transducers |
| title_full |
Backscatter coefficient estimation using highly focused ultrasound transducers |
| title_fullStr |
Backscatter coefficient estimation using highly focused ultrasound transducers |
| title_full_unstemmed |
Backscatter coefficient estimation using highly focused ultrasound transducers |
| title_sort |
Backscatter coefficient estimation using highly focused ultrasound transducers |
| author |
Panizo Ríos, Diego |
| author_facet |
Panizo Ríos, Diego |
| author_role |
author |
| dc.contributor.advisor.fl_str_mv |
Lavarello Montero, Roberto Janniel |
| dc.contributor.author.fl_str_mv |
Panizo Ríos, Diego |
| dc.subject.es_ES.fl_str_mv |
Métodos de simulación Transductores Ultrasonido |
| topic |
Métodos de simulación Transductores Ultrasonido https://purl.org/pe-repo/ocde/ford#2.02.05 |
| dc.subject.ocde.es_ES.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.02.05 |
| description |
The backscatter coefficient (BSC) is an intrinsic property that quantifies the amount of energy that is reflected by a material as function of the ultrasound wave frequency. BSCs have been proposed for decades for tissue characterization, along with quantitative ultrasound (QUS) parameters derived from BSCs that have been used to construct images that represent how these properties vary spatially. The availability of formulations based on weakly focusing conditions has resulted in a widespread use of large focal number transducers for BSC estimation. The use of highly focused transducers offers the possibility of improving the spatial resolution of BSC-based imaging. The model by Chen et al. [1] was developed for estimating BSCs using transducers of arbitrary focal number. However, to this date only preliminary experimental validation of this method has been performed. The goals of the present study are to analyze for the first time the accuracy of Chen’s [1] method when estimating BSCs using highly focused transducers through both simulations and experiments, and to analyze the accuracy on the estimation of QUS parameters derived from BSCs (specifically the effective scatterer size (ESD) and concentration (ESC)) applying the Chen et al. [1] model. To achieve these goals, a theoretical model of BSC synthesis based on the method of Chen et al. [1]. was derived and used with simulated data. The model considers frequency dependent diffraction patterns, and the scatterers in the synthetic data replicate the properties of solid spheres. In experiments, data obtained using highly focused transducers from a physical phantom containing glass beads was used. This experimental data was appropriately compensated for attenuation and transmission effects. The accuracy of Chen’s method was evaluated calculating the mean fractional error between the estimated and theoretical BSCs curves for both simulations and experiments. Also, the QUS parameters were estimated and compared with real known parameters. BSCs and QUS parameter estimates were obtained from regions of interest from both the transducer focus and throughout the transducer focal region. Finally, the sound speed and the transducer focus were varied in appropriate ranges when processing the data for the BSC and QUS values estimation in order to assess the robustness of the method to uncertainties in these parameters. The results showed that BSCs and QUS parameters can be accurately estimated using highly focused transducers if the appropriate model is used, with regions of interest not restricted to be centered at the focus but to the full extension of the -6-dB transducer focal region. It was also verified that well estimated parameters as the sound speed and transducer focus are necessary in order to obtain accurate BSCs and QUS parameters estimates. |
| publishDate |
2013 |
| dc.date.created.es_ES.fl_str_mv |
2013 |
| dc.date.accessioned.es_ES.fl_str_mv |
2014-05-26T20:25:20Z |
| dc.date.available.es_ES.fl_str_mv |
2014-05-26T20:25:20Z |
| dc.date.issued.fl_str_mv |
2014-05-26 |
| dc.type.es_ES.fl_str_mv |
info:eu-repo/semantics/masterThesis |
| format |
masterThesis |
| dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/20.500.12404/5339 |
| url |
http://hdl.handle.net/20.500.12404/5339 |
| dc.language.iso.es_ES.fl_str_mv |
eng |
| language |
eng |
| dc.relation.ispartof.fl_str_mv |
SUNEDU |
| dc.rights.es_ES.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.*.fl_str_mv |
http://creativecommons.org/licenses/by/2.5/pe/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by/2.5/pe/ |
| dc.publisher.es_ES.fl_str_mv |
Pontificia Universidad Católica del Perú |
| dc.publisher.country.es_ES.fl_str_mv |
PE |
| dc.source.none.fl_str_mv |
reponame:PUCP-Tesis instname:Pontificia Universidad Católica del Perú instacron:PUCP |
| instname_str |
Pontificia Universidad Católica del Perú |
| instacron_str |
PUCP |
| institution |
PUCP |
| reponame_str |
PUCP-Tesis |
| collection |
PUCP-Tesis |
| bitstream.url.fl_str_mv |
https://tesis.pucp.edu.pe/bitstreams/00ec41a1-b5ba-4523-b04b-08bfcd2a89f4/download https://tesis.pucp.edu.pe/bitstreams/86a391e3-6242-4e31-ab70-d23cf509bd27/download https://tesis.pucp.edu.pe/bitstreams/c1a4b3fa-a906-4ada-aa91-92c3fe183da3/download https://tesis.pucp.edu.pe/bitstreams/79df1d13-fa1b-49e9-a650-c5fb009c59a5/download https://tesis.pucp.edu.pe/bitstreams/d5dea272-65fa-4b29-b19c-5725ab34bf84/download |
| bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 ca9261256ae7826c40422e38c088eb87 1b6f96fc6482dbdf647fbc295b34d77f 0a29d942330b0894cb425930d21403f7 37898d864c69cb1d69a3e4888db7ecf2 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio de Tesis PUCP |
| repository.mail.fl_str_mv |
raul.sifuentes@pucp.pe |
| _version_ |
1839176470859087872 |
| spelling |
Lavarello Montero, Roberto JannielPanizo Ríos, Diego2014-05-26T20:25:20Z2014-05-26T20:25:20Z20132014-05-26http://hdl.handle.net/20.500.12404/5339The backscatter coefficient (BSC) is an intrinsic property that quantifies the amount of energy that is reflected by a material as function of the ultrasound wave frequency. BSCs have been proposed for decades for tissue characterization, along with quantitative ultrasound (QUS) parameters derived from BSCs that have been used to construct images that represent how these properties vary spatially. The availability of formulations based on weakly focusing conditions has resulted in a widespread use of large focal number transducers for BSC estimation. The use of highly focused transducers offers the possibility of improving the spatial resolution of BSC-based imaging. The model by Chen et al. [1] was developed for estimating BSCs using transducers of arbitrary focal number. However, to this date only preliminary experimental validation of this method has been performed. The goals of the present study are to analyze for the first time the accuracy of Chen’s [1] method when estimating BSCs using highly focused transducers through both simulations and experiments, and to analyze the accuracy on the estimation of QUS parameters derived from BSCs (specifically the effective scatterer size (ESD) and concentration (ESC)) applying the Chen et al. [1] model. To achieve these goals, a theoretical model of BSC synthesis based on the method of Chen et al. [1]. was derived and used with simulated data. The model considers frequency dependent diffraction patterns, and the scatterers in the synthetic data replicate the properties of solid spheres. In experiments, data obtained using highly focused transducers from a physical phantom containing glass beads was used. This experimental data was appropriately compensated for attenuation and transmission effects. The accuracy of Chen’s method was evaluated calculating the mean fractional error between the estimated and theoretical BSCs curves for both simulations and experiments. Also, the QUS parameters were estimated and compared with real known parameters. BSCs and QUS parameter estimates were obtained from regions of interest from both the transducer focus and throughout the transducer focal region. Finally, the sound speed and the transducer focus were varied in appropriate ranges when processing the data for the BSC and QUS values estimation in order to assess the robustness of the method to uncertainties in these parameters. The results showed that BSCs and QUS parameters can be accurately estimated using highly focused transducers if the appropriate model is used, with regions of interest not restricted to be centered at the focus but to the full extension of the -6-dB transducer focal region. It was also verified that well estimated parameters as the sound speed and transducer focus are necessary in order to obtain accurate BSCs and QUS parameters estimates.TesisengPontificia Universidad Católica del PerúPEinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/2.5/pe/Métodos de simulaciónTransductoresUltrasonidohttps://purl.org/pe-repo/ocde/ford#2.02.05Backscatter coefficient estimation using highly focused ultrasound transducersinfo:eu-repo/semantics/masterThesisreponame:PUCP-Tesisinstname:Pontificia Universidad Católica del Perúinstacron:PUCPSUNEDUMaestro en Procesamiento de señales e imágenes digitalesMaestríaPontificia Universidad Católica del Perú. Escuela de PosgradoProcesamiento de señales e imágenes digitales10544227613077https://purl.org/pe-repo/renati/level#maestrohttps://purl.org/pe-repo/renati/type#tesisLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://tesis.pucp.edu.pe/bitstreams/00ec41a1-b5ba-4523-b04b-08bfcd2a89f4/download8a4605be74aa9ea9d79846c1fba20a33MD53falseAnonymousREADORIGINALPANIZO_DIEGO_COEFFICIENT_ESTIMATION_HIGHLY_FOCUSED_ULTRASOUND_TRANSDUCERS.pdfPANIZO_DIEGO_COEFFICIENT_ESTIMATION_HIGHLY_FOCUSED_ULTRASOUND_TRANSDUCERS.pdfapplication/pdf607088https://tesis.pucp.edu.pe/bitstreams/86a391e3-6242-4e31-ab70-d23cf509bd27/downloadca9261256ae7826c40422e38c088eb87MD51trueAnonymousREADCC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81370https://tesis.pucp.edu.pe/bitstreams/c1a4b3fa-a906-4ada-aa91-92c3fe183da3/download1b6f96fc6482dbdf647fbc295b34d77fMD52falseAnonymousREADTEXTPANIZO_DIEGO_COEFFICIENT_ESTIMATION_HIGHLY_FOCUSED_ULTRASOUND_TRANSDUCERS.pdf.txtPANIZO_DIEGO_COEFFICIENT_ESTIMATION_HIGHLY_FOCUSED_ULTRASOUND_TRANSDUCERS.pdf.txtExtracted texttext/plain85313https://tesis.pucp.edu.pe/bitstreams/79df1d13-fa1b-49e9-a650-c5fb009c59a5/download0a29d942330b0894cb425930d21403f7MD56falseAnonymousREADTHUMBNAILPANIZO_DIEGO_COEFFICIENT_ESTIMATION_HIGHLY_FOCUSED_ULTRASOUND_TRANSDUCERS.pdf.jpgPANIZO_DIEGO_COEFFICIENT_ESTIMATION_HIGHLY_FOCUSED_ULTRASOUND_TRANSDUCERS.pdf.jpgIM Thumbnailimage/jpeg32618https://tesis.pucp.edu.pe/bitstreams/d5dea272-65fa-4b29-b19c-5725ab34bf84/download37898d864c69cb1d69a3e4888db7ecf2MD57falseAnonymousREAD20.500.12404/5339oai:tesis.pucp.edu.pe:20.500.12404/53392025-07-18 12:45:05.616http://creativecommons.org/licenses/by/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://tesis.pucp.edu.peRepositorio de Tesis PUCPraul.sifuentes@pucp.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 |
| score |
13.416544 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).