A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer
Descripción del Articulo
        An electrochemical sensor (CPE-IIHP) was developed for Cd(II) using a carbon paste electrode (CPE) impregnated with an ion-imprinted hybrid polymer (IIHP). A CPE-NIHP was also prepared for comparison. DPASV was used to optimize the sensor response and quantify Cd(II). The sensor presented a wide lin...
              
            
    
                        | Autores: | , , , , | 
|---|---|
| Formato: | artículo | 
| Fecha de Publicación: | 2021 | 
| Institución: | Consejo Nacional de Ciencia Tecnología e Innovación | 
| Repositorio: | CONCYTEC-Institucional | 
| Lenguaje: | inglés | 
| OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/2415 | 
| Enlace del recurso: | https://hdl.handle.net/20.500.12390/2415 https://doi.org/10.1002/elan.202100007 | 
| Nivel de acceso: | acceso abierto | 
| Materia: | Ion-imprinted polymer carbon paste electrode Cd(II) http://purl.org/pe-repo/ocde/ford#1.04.0 | 
| id | CONC_d3100c41af58043f01e8ed65cdeeaedd | 
|---|---|
| oai_identifier_str | oai:repositorio.concytec.gob.pe:20.500.12390/2415 | 
| network_acronym_str | CONC | 
| network_name_str | CONCYTEC-Institucional | 
| repository_id_str | 4689 | 
| dc.title.none.fl_str_mv | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer | 
| title | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer | 
| spellingShingle | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer Adauto A. Ion-imprinted polymer carbon paste electrode Cd(II) http://purl.org/pe-repo/ocde/ford#1.04.0 | 
| title_short | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer | 
| title_full | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer | 
| title_fullStr | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer | 
| title_full_unstemmed | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer | 
| title_sort | A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer | 
| author | Adauto A. | 
| author_facet | Adauto A. Wong A. Khan S. Picasso G. del Pilar Taboada Sotomayor M. | 
| author_role | author | 
| author2 | Wong A. Khan S. Picasso G. del Pilar Taboada Sotomayor M. | 
| author2_role | author author author author | 
| dc.contributor.author.fl_str_mv | Adauto A. Wong A. Khan S. Picasso G. del Pilar Taboada Sotomayor M. | 
| dc.subject.none.fl_str_mv | Ion-imprinted polymer | 
| topic | Ion-imprinted polymer carbon paste electrode Cd(II) http://purl.org/pe-repo/ocde/ford#1.04.0 | 
| dc.subject.es_PE.fl_str_mv | carbon paste electrode Cd(II) | 
| dc.subject.ocde.none.fl_str_mv | http://purl.org/pe-repo/ocde/ford#1.04.0 | 
| description | An electrochemical sensor (CPE-IIHP) was developed for Cd(II) using a carbon paste electrode (CPE) impregnated with an ion-imprinted hybrid polymer (IIHP). A CPE-NIHP was also prepared for comparison. DPASV was used to optimize the sensor response and quantify Cd(II). The sensor presented a wide linear range from low concentrations of Cd(II): 1 to 100 ?g L?1 and high concentrations of Cd(II): 2.75 to 5.0 mg L?1. Ions such as Co(II), Pb(II), Ni(II), Zn(II), Fe(II), Fe(III), Sn(II) and Cu(II), showed no variation in the Cd(II) signal. The CPE-IIHP was successfully applied in river and drinking water analysis, revealing the great potential for its application. | 
| publishDate | 2021 | 
| dc.date.accessioned.none.fl_str_mv | 2024-05-30T23:13:38Z | 
| dc.date.available.none.fl_str_mv | 2024-05-30T23:13:38Z | 
| dc.date.issued.fl_str_mv | 2021 | 
| dc.type.none.fl_str_mv | info:eu-repo/semantics/article | 
| format | article | 
| dc.identifier.uri.none.fl_str_mv | https://hdl.handle.net/20.500.12390/2415 | 
| dc.identifier.doi.none.fl_str_mv | https://doi.org/10.1002/elan.202100007 | 
| dc.identifier.scopus.none.fl_str_mv | 2-s2.0-85103058471 | 
| url | https://hdl.handle.net/20.500.12390/2415 https://doi.org/10.1002/elan.202100007 | 
| identifier_str_mv | 2-s2.0-85103058471 | 
| dc.language.iso.none.fl_str_mv | eng | 
| language | eng | 
| dc.relation.ispartof.none.fl_str_mv | urn:issn:1040-0397 | 
| dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess | 
| eu_rights_str_mv | openAccess | 
| dc.publisher.none.fl_str_mv | John Wiley and Sons Inc | 
| publisher.none.fl_str_mv | John Wiley and Sons Inc | 
| dc.source.none.fl_str_mv | reponame:CONCYTEC-Institucional instname:Consejo Nacional de Ciencia Tecnología e Innovación instacron:CONCYTEC | 
| instname_str | Consejo Nacional de Ciencia Tecnología e Innovación | 
| instacron_str | CONCYTEC | 
| institution | CONCYTEC | 
| reponame_str | CONCYTEC-Institucional | 
| collection | CONCYTEC-Institucional | 
| repository.name.fl_str_mv | Repositorio Institucional CONCYTEC | 
| repository.mail.fl_str_mv | repositorio@concytec.gob.pe | 
| _version_ | 1844883044717035520 | 
| spelling | Publicationrp05583600rp01044600rp05568600rp02497600rp05982600Adauto A.Wong A.Khan S.Picasso G.del Pilar Taboada Sotomayor M.2024-05-30T23:13:38Z2024-05-30T23:13:38Z2021https://hdl.handle.net/20.500.12390/2415https://doi.org/10.1002/elan.2021000072-s2.0-85103058471An electrochemical sensor (CPE-IIHP) was developed for Cd(II) using a carbon paste electrode (CPE) impregnated with an ion-imprinted hybrid polymer (IIHP). A CPE-NIHP was also prepared for comparison. DPASV was used to optimize the sensor response and quantify Cd(II). The sensor presented a wide linear range from low concentrations of Cd(II): 1 to 100 ?g L?1 and high concentrations of Cd(II): 2.75 to 5.0 mg L?1. Ions such as Co(II), Pb(II), Ni(II), Zn(II), Fe(II), Fe(III), Sn(II) and Cu(II), showed no variation in the Cd(II) signal. The CPE-IIHP was successfully applied in river and drinking water analysis, revealing the great potential for its application.Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengJohn Wiley and Sons Incurn:issn:1040-0397info:eu-repo/semantics/openAccessIon-imprinted polymercarbon paste electrode-1Cd(II)-1http://purl.org/pe-repo/ocde/ford#1.04.0-1A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymerinfo:eu-repo/semantics/articlereponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/2415oai:repositorio.concytec.gob.pe:20.500.12390/24152024-05-30 16:07:59.641http://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="ec348ce3-91f4-4aab-9fcf-ff6a117720d4"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>A Selective Electrochemical Sensor for the Detection of Cd(II) Based on a Carbon Paste Electrode Impregnated with a Novel Ion-imprinted Hybrid Polymer</Title> <PublishedIn> <Publication> <Title>urn:issn:1040-0397</Title> </Publication> </PublishedIn> <PublicationDate>2021</PublicationDate> <DOI>https://doi.org/10.1002/elan.202100007</DOI> <SCP-Number>2-s2.0-85103058471</SCP-Number> <Authors> <Author> <DisplayName>Adauto A.</DisplayName> <Person id="rp05583" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Wong A.</DisplayName> <Person id="rp01044" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Khan S.</DisplayName> <Person id="rp05568" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Picasso G.</DisplayName> <Person id="rp02497" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>del Pilar Taboada Sotomayor M.</DisplayName> <Person id="rp05982" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>John Wiley and Sons Inc</DisplayName> <OrgUnit /> </Publisher> </Publishers> <Keyword>Ion-imprinted polymer</Keyword> <Keyword>carbon paste electrode</Keyword> <Keyword>Cd(II)</Keyword> <Abstract>An electrochemical sensor (CPE-IIHP) was developed for Cd(II) using a carbon paste electrode (CPE) impregnated with an ion-imprinted hybrid polymer (IIHP). A CPE-NIHP was also prepared for comparison. DPASV was used to optimize the sensor response and quantify Cd(II). The sensor presented a wide linear range from low concentrations of Cd(II): 1 to 100 ?g L?1 and high concentrations of Cd(II): 2.75 to 5.0 mg L?1. Ions such as Co(II), Pb(II), Ni(II), Zn(II), Fe(II), Fe(III), Sn(II) and Cu(II), showed no variation in the Cd(II) signal. The CPE-IIHP was successfully applied in river and drinking water analysis, revealing the great potential for its application.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1 | 
| score | 13.410445 | 
 Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
    La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
 
   
   
             
            