Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church
Descripción del Articulo
This article presents the results of an experimental campaign using the flat jack technique in an adobe church called “Virgen de la Asuncion” located in Sacsamarca, Peru. The main mechanical properties of this construction were determined using the single and the double flat jack tests. The flat jac...
Autores: | , , |
---|---|
Formato: | capítulo de libro |
Fecha de Publicación: | 2019 |
Institución: | Consejo Nacional de Ciencia Tecnología e Innovación |
Repositorio: | CONCYTEC-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/519 |
Enlace del recurso: | https://hdl.handle.net/20.500.12390/519 https://doi.org/10.1007/978-3-319-99441-3_76 |
Nivel de acceso: | acceso abierto |
Materia: | Minor destructive test (MDT) Flat jack test Mechanical characterization Adobe buildings Heritage buildings https://purl.org/pe-repo/ocde/ford#2.01.00 |
id |
CONC_c5cf3ab023a15f8877015bf85ee33dd3 |
---|---|
oai_identifier_str |
oai:repositorio.concytec.gob.pe:20.500.12390/519 |
network_acronym_str |
CONC |
network_name_str |
CONCYTEC-Institucional |
repository_id_str |
4689 |
dc.title.none.fl_str_mv |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church |
title |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church |
spellingShingle |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church Tacas K. Minor destructive test (MDT) Flat jack test Mechanical characterization Adobe buildings Heritage buildings https://purl.org/pe-repo/ocde/ford#2.01.00 |
title_short |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church |
title_full |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church |
title_fullStr |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church |
title_full_unstemmed |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church |
title_sort |
Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church |
author |
Tacas K. |
author_facet |
Tacas K. Gonzales M. Aguilar R. |
author_role |
author |
author2 |
Gonzales M. Aguilar R. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Tacas K. Gonzales M. Aguilar R. |
dc.subject.none.fl_str_mv |
Minor destructive test (MDT) |
topic |
Minor destructive test (MDT) Flat jack test Mechanical characterization Adobe buildings Heritage buildings https://purl.org/pe-repo/ocde/ford#2.01.00 |
dc.subject.es_PE.fl_str_mv |
Flat jack test Mechanical characterization Adobe buildings Heritage buildings |
dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.01.00 |
description |
This article presents the results of an experimental campaign using the flat jack technique in an adobe church called “Virgen de la Asuncion” located in Sacsamarca, Peru. The main mechanical properties of this construction were determined using the single and the double flat jack tests. The flat jack test is considered as minor destructive test (MDT), which is appropriate for historical buildings due to the temporary and easily repairable damage generated. Single and double flat jack tests were carried out on the north and east facades of the church. The single flat jack test allowed the estimation of the local compressive stress levels through the continuous monitoring of the state of strain. The double flat jack test allowed determining the local stress-strain behavior in each facade of the church. The mechanical properties obtained in this research are similar to values obtained by other authors for historical adobe buildings using different methods. |
publishDate |
2019 |
dc.date.accessioned.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.available.none.fl_str_mv |
2024-05-30T23:13:38Z |
dc.date.issued.fl_str_mv |
2019 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/bookPart |
format |
bookPart |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12390/519 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1007/978-3-319-99441-3_76 |
dc.identifier.scopus.none.fl_str_mv |
2-s2.0-85052327006 |
url |
https://hdl.handle.net/20.500.12390/519 https://doi.org/10.1007/978-3-319-99441-3_76 |
identifier_str_mv |
2-s2.0-85052327006 |
dc.language.iso.none.fl_str_mv |
eng |
language |
eng |
dc.relation.ispartof.none.fl_str_mv |
RILEM Bookseries |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Springer Netherlands |
publisher.none.fl_str_mv |
Springer Netherlands |
dc.source.none.fl_str_mv |
reponame:CONCYTEC-Institucional instname:Consejo Nacional de Ciencia Tecnología e Innovación instacron:CONCYTEC |
instname_str |
Consejo Nacional de Ciencia Tecnología e Innovación |
instacron_str |
CONCYTEC |
institution |
CONCYTEC |
reponame_str |
CONCYTEC-Institucional |
collection |
CONCYTEC-Institucional |
repository.name.fl_str_mv |
Repositorio Institucional CONCYTEC |
repository.mail.fl_str_mv |
repositorio@concytec.gob.pe |
_version_ |
1844883118104772608 |
spelling |
Publicationrp00823600rp00824600rp00404500Tacas K.Gonzales M.Aguilar R.2024-05-30T23:13:38Z2024-05-30T23:13:38Z2019https://hdl.handle.net/20.500.12390/519https://doi.org/10.1007/978-3-319-99441-3_762-s2.0-85052327006This article presents the results of an experimental campaign using the flat jack technique in an adobe church called “Virgen de la Asuncion” located in Sacsamarca, Peru. The main mechanical properties of this construction were determined using the single and the double flat jack tests. The flat jack test is considered as minor destructive test (MDT), which is appropriate for historical buildings due to the temporary and easily repairable damage generated. Single and double flat jack tests were carried out on the north and east facades of the church. The single flat jack test allowed the estimation of the local compressive stress levels through the continuous monitoring of the state of strain. The double flat jack test allowed determining the local stress-strain behavior in each facade of the church. The mechanical properties obtained in this research are similar to values obtained by other authors for historical adobe buildings using different methods.Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - ConcytecengSpringer NetherlandsRILEM Bookseriesinfo:eu-repo/semantics/openAccessMinor destructive test (MDT)Flat jack test-1Mechanical characterization-1Adobe buildings-1Heritage buildings-1https://purl.org/pe-repo/ocde/ford#2.01.00-1Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Churchinfo:eu-repo/semantics/bookPartreponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC20.500.12390/519oai:repositorio.concytec.gob.pe:20.500.12390/5192024-05-30 15:57:44.285http://purl.org/coar/access_right/c_14cbinfo:eu-repo/semantics/closedAccessmetadata only accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="6a3c70c9-cffe-4806-80ac-f4621b8b6592"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>Mechanical Characterization of Adobe Constructions Using Flat Jack Tests: Case Study of the Virgen de la Asunción de Sacsamarca Church</Title> <PublishedIn> <Publication> <Title>RILEM Bookseries</Title> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <DOI>https://doi.org/10.1007/978-3-319-99441-3_76</DOI> <SCP-Number>2-s2.0-85052327006</SCP-Number> <Authors> <Author> <DisplayName>Tacas K.</DisplayName> <Person id="rp00823" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Gonzales M.</DisplayName> <Person id="rp00824" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Aguilar R.</DisplayName> <Person id="rp00404" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Springer Netherlands</DisplayName> <OrgUnit /> </Publisher> </Publishers> <Keyword>Minor destructive test (MDT)</Keyword> <Keyword>Flat jack test</Keyword> <Keyword>Mechanical characterization</Keyword> <Keyword>Adobe buildings</Keyword> <Keyword>Heritage buildings</Keyword> <Abstract>This article presents the results of an experimental campaign using the flat jack technique in an adobe church called “Virgen de la Asuncion” located in Sacsamarca, Peru. The main mechanical properties of this construction were determined using the single and the double flat jack tests. The flat jack test is considered as minor destructive test (MDT), which is appropriate for historical buildings due to the temporary and easily repairable damage generated. Single and double flat jack tests were carried out on the north and east facades of the church. The single flat jack test allowed the estimation of the local compressive stress levels through the continuous monitoring of the state of strain. The double flat jack test allowed determining the local stress-strain behavior in each facade of the church. The mechanical properties obtained in this research are similar to values obtained by other authors for historical adobe buildings using different methods.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1 |
score |
13.377112 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).