A low-cost measurement device for recording perceptions of thermal comfort

Descripción del Articulo

In this article, we describe the implementation of a low-cost device that registers perceptions of thermal comfort. The parameters of relative humidity (RH), temperature, thermal sensation (cold, cool, neutral, warn, hot) and clothing worn by people are collected. The design and validation of the de...

Descripción completa

Detalles Bibliográficos
Autores: Molina J.R., Nakama V.L., Lefebvre G.
Formato: artículo
Fecha de Publicación:2020
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/2589
Enlace del recurso:https://hdl.handle.net/20.500.12390/2589
https://doi.org/10.1088/1742-6596/1433/1/012006
Nivel de acceso:acceso abierto
Materia:Thermal Comfort
Hot Temperature
http://purl.org/pe-repo/ocde/ford#1.05.10
id CONC_2d7843f0a29ae0fb8d8907f3d2966fcc
oai_identifier_str oai:repositorio.concytec.gob.pe:20.500.12390/2589
network_acronym_str CONC
network_name_str CONCYTEC-Institucional
repository_id_str 4689
dc.title.none.fl_str_mv A low-cost measurement device for recording perceptions of thermal comfort
title A low-cost measurement device for recording perceptions of thermal comfort
spellingShingle A low-cost measurement device for recording perceptions of thermal comfort
Molina J.R.
Thermal Comfort
Hot Temperature
http://purl.org/pe-repo/ocde/ford#1.05.10
title_short A low-cost measurement device for recording perceptions of thermal comfort
title_full A low-cost measurement device for recording perceptions of thermal comfort
title_fullStr A low-cost measurement device for recording perceptions of thermal comfort
title_full_unstemmed A low-cost measurement device for recording perceptions of thermal comfort
title_sort A low-cost measurement device for recording perceptions of thermal comfort
author Molina J.R.
author_facet Molina J.R.
Nakama V.L.
Lefebvre G.
author_role author
author2 Nakama V.L.
Lefebvre G.
author2_role author
author
dc.contributor.author.fl_str_mv Molina J.R.
Nakama V.L.
Lefebvre G.
dc.subject.none.fl_str_mv Thermal Comfort
topic Thermal Comfort
Hot Temperature
http://purl.org/pe-repo/ocde/ford#1.05.10
dc.subject.es_PE.fl_str_mv Hot Temperature
dc.subject.ocde.none.fl_str_mv http://purl.org/pe-repo/ocde/ford#1.05.10
description In this article, we describe the implementation of a low-cost device that registers perceptions of thermal comfort. The parameters of relative humidity (RH), temperature, thermal sensation (cold, cool, neutral, warn, hot) and clothing worn by people are collected. The design and validation of the device in an indoor environment are explained, and the calibration curves of the temperature and relative humidity sensors are obtained. The measurement results for the device from 10 people are shown. The study was carried out in the village of Imata (high Andean zone), at 4700 masl in the south of Peru. © Published under licence by IOP Publishing Ltd.
publishDate 2020
dc.date.accessioned.none.fl_str_mv 2024-05-30T23:13:38Z
dc.date.available.none.fl_str_mv 2024-05-30T23:13:38Z
dc.date.issued.fl_str_mv 2020
dc.type.none.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12390/2589
dc.identifier.doi.none.fl_str_mv https://doi.org/10.1088/1742-6596/1433/1/012006
dc.identifier.scopus.none.fl_str_mv 2-s2.0-85078985181
url https://hdl.handle.net/20.500.12390/2589
https://doi.org/10.1088/1742-6596/1433/1/012006
identifier_str_mv 2-s2.0-85078985181
dc.language.iso.none.fl_str_mv eng
language eng
dc.relation.ispartof.none.fl_str_mv Journal of Physics: Conference Series
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.none.fl_str_mv https://creativecommons.org/licenses/by/3.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/3.0/
dc.publisher.none.fl_str_mv Institute of Physics Publishing
publisher.none.fl_str_mv Institute of Physics Publishing
dc.source.none.fl_str_mv reponame:CONCYTEC-Institucional
instname:Consejo Nacional de Ciencia Tecnología e Innovación
instacron:CONCYTEC
instname_str Consejo Nacional de Ciencia Tecnología e Innovación
instacron_str CONCYTEC
institution CONCYTEC
reponame_str CONCYTEC-Institucional
collection CONCYTEC-Institucional
bitstream.url.fl_str_mv https://repositorio.concytec.gob.pe/bitstreams/ba3b4719-0c0d-4110-a518-3c939c424ee5/download
https://repositorio.concytec.gob.pe/bitstreams/30433e5a-ed03-45f4-884e-e9eb447912a7/download
https://repositorio.concytec.gob.pe/bitstreams/2aee258d-58fe-4bdd-a8a1-5cd5ae1df59b/download
bitstream.checksum.fl_str_mv 9ac675af212c5d0c2653a126a6438242
64b4ba1cb897963218b3d95348b5be3b
4c7dac855b810747579e330bc0997cc7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional CONCYTEC
repository.mail.fl_str_mv repositorio@concytec.gob.pe
_version_ 1844883040349716480
spelling Publicationrp05903600rp06667600rp05904600Molina J.R.Nakama V.L.Lefebvre G.2024-05-30T23:13:38Z2024-05-30T23:13:38Z2020https://hdl.handle.net/20.500.12390/2589https://doi.org/10.1088/1742-6596/1433/1/0120062-s2.0-85078985181In this article, we describe the implementation of a low-cost device that registers perceptions of thermal comfort. The parameters of relative humidity (RH), temperature, thermal sensation (cold, cool, neutral, warn, hot) and clothing worn by people are collected. The design and validation of the device in an indoor environment are explained, and the calibration curves of the temperature and relative humidity sensors are obtained. The measurement results for the device from 10 people are shown. The study was carried out in the village of Imata (high Andean zone), at 4700 masl in the south of Peru. © Published under licence by IOP Publishing Ltd.Fondo Nacional de Desarrollo Científico y Tecnológico - FondecytengInstitute of Physics PublishingJournal of Physics: Conference Seriesinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/3.0/Thermal ComfortHot Temperature-1http://purl.org/pe-repo/ocde/ford#1.05.10-1A low-cost measurement device for recording perceptions of thermal comfortinfo:eu-repo/semantics/articlereponame:CONCYTEC-Institucionalinstname:Consejo Nacional de Ciencia Tecnología e Innovacióninstacron:CONCYTEC#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#ORIGINALA low-cost measurement device for recording.pdfA low-cost measurement device for recording.pdfapplication/pdf1329154https://repositorio.concytec.gob.pe/bitstreams/ba3b4719-0c0d-4110-a518-3c939c424ee5/download9ac675af212c5d0c2653a126a6438242MD51TEXTA low-cost measurement device for recording.pdf.txtA low-cost measurement device for recording.pdf.txtExtracted texttext/plain23682https://repositorio.concytec.gob.pe/bitstreams/30433e5a-ed03-45f4-884e-e9eb447912a7/download64b4ba1cb897963218b3d95348b5be3bMD52THUMBNAILA low-cost measurement device for recording.pdf.jpgA low-cost measurement device for recording.pdf.jpgGenerated Thumbnailimage/jpeg5559https://repositorio.concytec.gob.pe/bitstreams/2aee258d-58fe-4bdd-a8a1-5cd5ae1df59b/download4c7dac855b810747579e330bc0997cc7MD5320.500.12390/2589oai:repositorio.concytec.gob.pe:20.500.12390/25892025-01-15 22:00:47.225https://creativecommons.org/licenses/by/3.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessopen accesshttps://repositorio.concytec.gob.peRepositorio Institucional CONCYTECrepositorio@concytec.gob.pe#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#<Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="e038ebf5-ef74-41bd-9d75-7d0251f63428"> <Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843</Type> <Language>eng</Language> <Title>A low-cost measurement device for recording perceptions of thermal comfort</Title> <PublishedIn> <Publication> <Title>Journal of Physics: Conference Series</Title> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <DOI>https://doi.org/10.1088/1742-6596/1433/1/012006</DOI> <SCP-Number>2-s2.0-85078985181</SCP-Number> <Authors> <Author> <DisplayName>Molina J.R.</DisplayName> <Person id="rp05903" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Nakama V.L.</DisplayName> <Person id="rp06667" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> <Author> <DisplayName>Lefebvre G.</DisplayName> <Person id="rp05904" /> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Institute of Physics Publishing</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by/3.0/</License> <Keyword>Thermal Comfort</Keyword> <Keyword>Hot Temperature</Keyword> <Abstract>In this article, we describe the implementation of a low-cost device that registers perceptions of thermal comfort. The parameters of relative humidity (RH), temperature, thermal sensation (cold, cool, neutral, warn, hot) and clothing worn by people are collected. The design and validation of the device in an indoor environment are explained, and the calibration curves of the temperature and relative humidity sensors are obtained. The measurement results for the device from 10 people are shown. The study was carried out in the village of Imata (high Andean zone), at 4700 masl in the south of Peru. © Published under licence by IOP Publishing Ltd.</Abstract> <Access xmlns="http://purl.org/coar/access_right" > </Access> </Publication> -1
score 13.444865
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).