Implementation of a four probes measuring system to determine the resistivity of thin films with temperature dependence

Descripción del Articulo

Resistivity measurements in thin film samples depending on the temperature and on the lm thickness is always a subject of interest, above all when it comes to new materials. This work presents the implementation of a measuring system for thin fi lm resistivity based on four probes showing the depend...

Descripción completa

Detalles Bibliográficos
Autor: Salas Casapino, Carlos Alberto
Formato: tesis de maestría
Fecha de Publicación:2017
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/1826
Enlace del recurso:https://hdl.handle.net/20.500.12390/1826
Nivel de acceso:acceso abierto
Materia:Resistividad
Películas delgadas
https://purl.org/pe-repo/ocde/ford#2.00.00
Descripción
Sumario:Resistivity measurements in thin film samples depending on the temperature and on the lm thickness is always a subject of interest, above all when it comes to new materials. This work presents the implementation of a measuring system for thin fi lm resistivity based on four probes showing the dependency of the resistivity on the temperature as well as on the film thickness. In order to change the temperature of the samples, a heat source based on a Peltier element was implemented into the measuring system. A Graphical User Interface using a LabVIEW software controls all the devices of the measuring system and allows the user to calculate the thin lm resistivity choosing between four measuring method: Van der Pauw, Modi ed Van der Pauw, Linear Van der Pauw and Linear Four Probes methods. Resistivity in aluminum and tungsten thin lm samples with 100, 300, and 600 nm thickness were measured at temperatures between 303K and 373K with increments of 5 K. The results obtained are higher than bulk resistivity values and agrees with the present theory. Moreover, it is shown that the resistivity values obtained and its corresponding temperature coeficients increases as the film thickness decreases.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).