Free Hardware based System for Air Quality and CO2 Monitoring
Descripción del Articulo
Due to the increase in air pollution, especially in Latin American countries of low and middle income, great environmental and health risks have been generated, highlighting that there is more pollution in closed environments. Given this problem, it has been proposed to develop a system based on fre...
Autores: | , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2022 |
Institución: | Universidad Autónoma del Perú |
Repositorio: | AUTONOMA-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.autonoma.edu.pe:20.500.13067/1827 |
Enlace del recurso: | https://hdl.handle.net/20.500.13067/1827 https://doi.org/10.14569/IJACSA.2022.0130244 |
Nivel de acceso: | acceso abierto |
Materia: | Air quality Air pollution CO2 Control system Free hardware V-model https://purl.org/pe-repo/ocde/ford#2.02.04 |
id |
AUTO_d23521b3305ed524028a095ec1d7c281 |
---|---|
oai_identifier_str |
oai:repositorio.autonoma.edu.pe:20.500.13067/1827 |
network_acronym_str |
AUTO |
network_name_str |
AUTONOMA-Institucional |
repository_id_str |
4774 |
spelling |
Alvarez-Mendoza, CristhoperVilchez-Lucana, JhonSierra-Liñan, FernandoCabanillas-Carbonell, Michael2022-05-02T14:46:38Z2022-05-02T14:46:38Z2022Alvarez-Mendoza, C., Vilchez-Lucana, J., Sierra-Liñan, F., & Cabanillas-Carbonell, M. (2022). Free Hardware based System for Air Quality and CO2 Monitoring. International Journal of Advanced Computer Science and Applications, 13(2).2156-5570https://hdl.handle.net/20.500.13067/1827International Journal of Advanced Computer Science and Applicationshttps://doi.org/10.14569/IJACSA.2022.0130244Due to the increase in air pollution, especially in Latin American countries of low and middle income, great environmental and health risks have been generated, highlighting that there is more pollution in closed environments. Given this problem, it has been proposed to develop a system based on free hardware for monitoring air quality and CO2, in order to reduce the levels of air pollution in a closed environment, improving the quality of life of people and contributing to the awareness of the damage caused to the environment by the hand of man himself. The system is based on V-Model, complemented with a ventilation prototype implemented with sensors and an application for its respective monitoring. The sample collected in the present investigation was non-probabilistic, derived from the reports of air indicators during 15 days with specific schedules of 9am, 1pm and 6pm. The results obtained indicated that the air quality decreased to 670 ppm, as well as the collection time decreased to 5 seconds and finally the presence of CO2 was reduced to 650 ppm after the implementation of the system, achieving to be within the standards recommended by the World Health Organization.application/pdfengThe Science and Information OrganizationPEinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-nd/4.0/AUTONOMA132377384reponame:AUTONOMA-Institucionalinstname:Universidad Autónoma del Perúinstacron:AUTONOMAAir qualityAir pollutionCO2Control systemFree hardwareV-modelhttps://purl.org/pe-repo/ocde/ford#2.02.04Free Hardware based System for Air Quality and CO2 Monitoringinfo:eu-repo/semantics/articlehttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85126087998&doi=10.14569%2fIJACSA.2022.0130244&partnerID=40&md5TEXTFree-Hardware-based-System-for-Air-Quality-and-CO2.pdf.txtFree-Hardware-based-System-for-Air-Quality-and-CO2.pdf.txtExtracted texttext/plain30905http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/3/Free-Hardware-based-System-for-Air-Quality-and-CO2.pdf.txt3735ad4c878055875baf4cea2eca2b4dMD53THUMBNAILFree-Hardware-based-System-for-Air-Quality-and-CO2.pdf.jpgFree-Hardware-based-System-for-Air-Quality-and-CO2.pdf.jpgGenerated Thumbnailimage/jpeg7911http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/4/Free-Hardware-based-System-for-Air-Quality-and-CO2.pdf.jpgf10b3f86c876f37644558dc0a63640e7MD54ORIGINALFree-Hardware-based-System-for-Air-Quality-and-CO2.pdfFree-Hardware-based-System-for-Air-Quality-and-CO2.pdfArtículoapplication/pdf1054137http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/1/Free-Hardware-based-System-for-Air-Quality-and-CO2.pdf305bd0a2cba5063d97bbd28365b31d5fMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-885http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/2/license.txt9243398ff393db1861c890baeaeee5f9MD5220.500.13067/1827oai:repositorio.autonoma.edu.pe:20.500.13067/18272022-05-03 03:00:32.033Repositorio de la Universidad Autonoma del Perúrepositorio@autonoma.pe |
dc.title.es_PE.fl_str_mv |
Free Hardware based System for Air Quality and CO2 Monitoring |
title |
Free Hardware based System for Air Quality and CO2 Monitoring |
spellingShingle |
Free Hardware based System for Air Quality and CO2 Monitoring Alvarez-Mendoza, Cristhoper Air quality Air pollution CO2 Control system Free hardware V-model https://purl.org/pe-repo/ocde/ford#2.02.04 |
title_short |
Free Hardware based System for Air Quality and CO2 Monitoring |
title_full |
Free Hardware based System for Air Quality and CO2 Monitoring |
title_fullStr |
Free Hardware based System for Air Quality and CO2 Monitoring |
title_full_unstemmed |
Free Hardware based System for Air Quality and CO2 Monitoring |
title_sort |
Free Hardware based System for Air Quality and CO2 Monitoring |
author |
Alvarez-Mendoza, Cristhoper |
author_facet |
Alvarez-Mendoza, Cristhoper Vilchez-Lucana, Jhon Sierra-Liñan, Fernando Cabanillas-Carbonell, Michael |
author_role |
author |
author2 |
Vilchez-Lucana, Jhon Sierra-Liñan, Fernando Cabanillas-Carbonell, Michael |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Alvarez-Mendoza, Cristhoper Vilchez-Lucana, Jhon Sierra-Liñan, Fernando Cabanillas-Carbonell, Michael |
dc.subject.es_PE.fl_str_mv |
Air quality Air pollution CO2 Control system Free hardware V-model |
topic |
Air quality Air pollution CO2 Control system Free hardware V-model https://purl.org/pe-repo/ocde/ford#2.02.04 |
dc.subject.ocde.es_PE.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.02.04 |
description |
Due to the increase in air pollution, especially in Latin American countries of low and middle income, great environmental and health risks have been generated, highlighting that there is more pollution in closed environments. Given this problem, it has been proposed to develop a system based on free hardware for monitoring air quality and CO2, in order to reduce the levels of air pollution in a closed environment, improving the quality of life of people and contributing to the awareness of the damage caused to the environment by the hand of man himself. The system is based on V-Model, complemented with a ventilation prototype implemented with sensors and an application for its respective monitoring. The sample collected in the present investigation was non-probabilistic, derived from the reports of air indicators during 15 days with specific schedules of 9am, 1pm and 6pm. The results obtained indicated that the air quality decreased to 670 ppm, as well as the collection time decreased to 5 seconds and finally the presence of CO2 was reduced to 650 ppm after the implementation of the system, achieving to be within the standards recommended by the World Health Organization. |
publishDate |
2022 |
dc.date.accessioned.none.fl_str_mv |
2022-05-02T14:46:38Z |
dc.date.available.none.fl_str_mv |
2022-05-02T14:46:38Z |
dc.date.issued.fl_str_mv |
2022 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
dc.identifier.citation.es_PE.fl_str_mv |
Alvarez-Mendoza, C., Vilchez-Lucana, J., Sierra-Liñan, F., & Cabanillas-Carbonell, M. (2022). Free Hardware based System for Air Quality and CO2 Monitoring. International Journal of Advanced Computer Science and Applications, 13(2). |
dc.identifier.issn.none.fl_str_mv |
2156-5570 |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.13067/1827 |
dc.identifier.journal.es_PE.fl_str_mv |
International Journal of Advanced Computer Science and Applications |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.14569/IJACSA.2022.0130244 |
identifier_str_mv |
Alvarez-Mendoza, C., Vilchez-Lucana, J., Sierra-Liñan, F., & Cabanillas-Carbonell, M. (2022). Free Hardware based System for Air Quality and CO2 Monitoring. International Journal of Advanced Computer Science and Applications, 13(2). 2156-5570 International Journal of Advanced Computer Science and Applications |
url |
https://hdl.handle.net/20.500.13067/1827 https://doi.org/10.14569/IJACSA.2022.0130244 |
dc.language.iso.es_PE.fl_str_mv |
eng |
language |
eng |
dc.relation.url.es_PE.fl_str_mv |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85126087998&doi=10.14569%2fIJACSA.2022.0130244&partnerID=40&md5 |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
dc.format.es_PE.fl_str_mv |
application/pdf |
dc.publisher.es_PE.fl_str_mv |
The Science and Information Organization |
dc.publisher.country.es_PE.fl_str_mv |
PE |
dc.source.es_PE.fl_str_mv |
AUTONOMA |
dc.source.none.fl_str_mv |
reponame:AUTONOMA-Institucional instname:Universidad Autónoma del Perú instacron:AUTONOMA |
instname_str |
Universidad Autónoma del Perú |
instacron_str |
AUTONOMA |
institution |
AUTONOMA |
reponame_str |
AUTONOMA-Institucional |
collection |
AUTONOMA-Institucional |
dc.source.volume.es_PE.fl_str_mv |
13 |
dc.source.issue.es_PE.fl_str_mv |
2 |
dc.source.beginpage.es_PE.fl_str_mv |
377 |
dc.source.endpage.es_PE.fl_str_mv |
384 |
bitstream.url.fl_str_mv |
http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/3/Free-Hardware-based-System-for-Air-Quality-and-CO2.pdf.txt http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/4/Free-Hardware-based-System-for-Air-Quality-and-CO2.pdf.jpg http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/1/Free-Hardware-based-System-for-Air-Quality-and-CO2.pdf http://repositorio.autonoma.edu.pe/bitstream/20.500.13067/1827/2/license.txt |
bitstream.checksum.fl_str_mv |
3735ad4c878055875baf4cea2eca2b4d f10b3f86c876f37644558dc0a63640e7 305bd0a2cba5063d97bbd28365b31d5f 9243398ff393db1861c890baeaeee5f9 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio de la Universidad Autonoma del Perú |
repository.mail.fl_str_mv |
repositorio@autonoma.pe |
_version_ |
1835915360839139328 |
score |
13.882472 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).