Quality of the design of removable partial dentures in working models
Descripción del Articulo
Objective. was to determine the quality of removable partial denture (RP) design in working models performed in Huánuco as of 2017 according to the years of experience of the professionals. Methods. This is a descriptive level, cross-sectional, basic and prospective study. Under a quantitative appro...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Universidad de Huánuco |
Repositorio: | Revista UDH - Revista Peruana de Ciencias de la Salud |
Lenguaje: | español |
OAI Identifier: | oai:ojs.revistas.udh.edu.pe:article/19 |
Enlace del recurso: | http://revistas.udh.edu.pe/index.php/RPCS/article/view/19 |
Nivel de acceso: | acceso abierto |
Materia: | humanos Dentadura parcial Retirable Laboratorios Dentalesx Laboratorios Dentales Arco dental Estudios prospectivos Estudios de muestreo Diseño de la investigación Dentistas Personal de laboratorio |
id |
2707-6954_3707da5d5625b366169001a8c89ac843 |
---|---|
oai_identifier_str |
oai:ojs.revistas.udh.edu.pe:article/19 |
network_acronym_str |
2707-6954 |
repository_id_str |
|
network_name_str |
Revista UDH - Revista Peruana de Ciencias de la Salud |
dc.title.none.fl_str_mv |
Quality of the design of removable partial dentures in working models Calidad del diseño de prótesis parcial removible en modelos de trabajo Qualidade do desenho da prótese parcial removível em modelos de trabalho |
title |
Quality of the design of removable partial dentures in working models |
spellingShingle |
Quality of the design of removable partial dentures in working models Calzada Gonzales, Nancy humanos Dentadura parcial Retirable Laboratorios Dentalesx Laboratorios Dentales Arco dental Estudios prospectivos Estudios de muestreo Diseño de la investigación Dentistas Personal de laboratorio |
title_short |
Quality of the design of removable partial dentures in working models |
title_full |
Quality of the design of removable partial dentures in working models |
title_fullStr |
Quality of the design of removable partial dentures in working models |
title_full_unstemmed |
Quality of the design of removable partial dentures in working models |
title_sort |
Quality of the design of removable partial dentures in working models |
dc.creator.none.fl_str_mv |
Calzada Gonzales, Nancy Ortega-Buitron, Marisol |
author |
Calzada Gonzales, Nancy |
author_facet |
Calzada Gonzales, Nancy Ortega-Buitron, Marisol |
author_role |
author |
author2 |
Ortega-Buitron, Marisol |
author2_role |
author |
dc.subject.none.fl_str_mv |
humanos Dentadura parcial Retirable Laboratorios Dentalesx Laboratorios Dentales Arco dental Estudios prospectivos Estudios de muestreo Diseño de la investigación Dentistas Personal de laboratorio |
topic |
humanos Dentadura parcial Retirable Laboratorios Dentalesx Laboratorios Dentales Arco dental Estudios prospectivos Estudios de muestreo Diseño de la investigación Dentistas Personal de laboratorio |
dc.description.none.fl_txt_mv |
Objective. was to determine the quality of removable partial denture (RP) design in working models performed in Huánuco as of 2017 according to the years of experience of the professionals. Methods. This is a descriptive level, cross-sectional, basic and prospective study. Under a quantitative approach, 280 working models for the fabrication of removable partial dentures were included in the study. Samples were collected in dental laboratories in the city of Huánuco. The components of the PPR design were observed for each sample. Descriptive statistics were applied. Results. 73 (91.3 %) did not carry out the shipping order (instructions from the dental professional about the design that the PPR should have), delegating the choice of the design to the dental laboratory technician and in a lower percentage did the instructions for the elaboration of the PPR 7 (8.8 %), 51 working models were upper dental arches and in a lower percentage, 29 (36.3 %) were the lower dental arches. The design quality of the removable partial denture bases in working models was acceptable in a total of 46 models. Conclusion. The quality of the design of the removable partial dentures was incorrect in a high percentage of cases; the components that make up the prosthesis did not comply with the ideal characteristics. 22.86 % of the dentists sent the working models with the design for the fabrication of the removable partial prosthesis. Objetivo. fue determinar la calidad del diseño de la prótesis parcial removible (PPR) en modelos de trabajo realizados en Huánuco al 2017 de acuerdo a los años de experiencia de los profesionales. Métodos. Se trata de un estudio de nivel descriptivo, de tipo transversal, básico y prospectivo. Bajo un enfoque cuantitativo, fueron incluidos en el estudio 280 modelos de trabajo para la confección de las prótesis parciales removibles. Se recolectaron las muestras en los laboratorios dentales de la ciudad de Huánuco. De cada muestra se observó los componentes del diseño de PPR. Se aplicó la estadística descriptiva. Resultados. 73 (91,3 %) no realizaron orden de envío (instrucciones del profesional odontólogo acerca del diseño que debe tener la PPR), delegando la elección del diseño al técnico del laboratorio dental y en un menor porcentaje lo hicieron las instrucciones para la elaboración de la PPR 7 (8,8 %), 51 modelos de trabajo fueron arcos dentarios superiores y en un menor porcentaje, 29 (36,3 %) fueron los arcos dentarios inferiores. La calidad de diseño de las bases de las prótesis parciales removibles en modelos de trabajo, fue aceptable un total de 46 modelos. Conclusión. La calidad del diseño de las prótesis parciales removibles en un alto porcentaje fue incorrecta, no cumplen con características ideales los componentes que lo conforman. El 22,86 % de los odontólogos envían los modelos de trabajo con diseño para la confección de la prótesis parcial removible. Objetivo. era determinar a qualidade do design da prótese parcial removível (RP) nos modelos de trabalho feitos em Huánuco até 2017, de acordo com os anos de experiência dos profissionais. Métodos. Este é um estudo descritivo de nível, transversal, básico e prospectivo. Sob uma abordagem quantitativa, 280 modelos de trabalho para a fabricação de próteses parciais removíveis foram incluídos no estudo. As amostras foram coletadas em laboratórios odontológicos na cidade de Huánuco. Os componentes do projeto do PPR foram observados para cada amostra. Foram aplicadas estatísticas descritivas. Resultados. 73 (91,3%) não realizou a ordem de envio (instruções do profissional odontológico sobre o projeto que o PPR deveria ter), delegando a escolha do projeto ao técnico de laboratório dentário e em uma porcentagem inferior, 7 (8,8%) fez as instruções para a elaboração do PPR, 51 modelos de trabalho eram arcos dentários superiores e em uma porcentagem inferior, 29 (36,3%) eram arcos dentários inferiores. A qualidade do projeto das bases de dentadura parcial removíveis em modelos de trabalho foi aceitável em um total de 46 modelos. Conclusão. A qualidade do projeto da prótese parcial removível foi incorreta em uma alta porcentagem de casos, cujos componentes não cumprem com as características ideais. 22,86 % dos dentistas enviaram os modelos de trabalho com o desenho para a fabricação da prótese parcial removível. |
description |
Objective. was to determine the quality of removable partial denture (RP) design in working models performed in Huánuco as of 2017 according to the years of experience of the professionals. Methods. This is a descriptive level, cross-sectional, basic and prospective study. Under a quantitative approach, 280 working models for the fabrication of removable partial dentures were included in the study. Samples were collected in dental laboratories in the city of Huánuco. The components of the PPR design were observed for each sample. Descriptive statistics were applied. Results. 73 (91.3 %) did not carry out the shipping order (instructions from the dental professional about the design that the PPR should have), delegating the choice of the design to the dental laboratory technician and in a lower percentage did the instructions for the elaboration of the PPR 7 (8.8 %), 51 working models were upper dental arches and in a lower percentage, 29 (36.3 %) were the lower dental arches. The design quality of the removable partial denture bases in working models was acceptable in a total of 46 models. Conclusion. The quality of the design of the removable partial dentures was incorrect in a high percentage of cases; the components that make up the prosthesis did not comply with the ideal characteristics. 22.86 % of the dentists sent the working models with the design for the fabrication of the removable partial prosthesis. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-06-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://revistas.udh.edu.pe/index.php/RPCS/article/view/19 10.37711/rpcs.2019.1.2.19 |
url |
http://revistas.udh.edu.pe/index.php/RPCS/article/view/19 |
identifier_str_mv |
10.37711/rpcs.2019.1.2.19 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
http://revistas.udh.edu.pe/index.php/RPCS/article/view/19/37 http://revistas.udh.edu.pe/index.php/RPCS/article/view/19/84 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf text/html |
dc.publisher.none.fl_str_mv |
UNIVERSIDAD DE HUÁNUCO |
publisher.none.fl_str_mv |
UNIVERSIDAD DE HUÁNUCO |
dc.source.none.fl_str_mv |
Revista Peruana de Ciencias de la Salud; Vol. 1 Núm. 2 (2019): Revista Peruana de Ciencias de la Salud (Abr - Jun); 69-74 Revista Peruana de Ciencias de la Salud; Vol. 1 Núm. 2 (2019): Revista Peruana de Ciencias de la Salud (Abr - Jun); 69-74 Revista Peruana de Ciencias de la Salud; Vol. 1 Núm. 2 (2019): Revista Peruana de Ciencias de la Salud (Abr - Jun); 69-74 2707-6954 2707-6946 reponame:Revista UDH - Revista Peruana de Ciencias de la Salud instname:Universidad de Huánuco instacron:UDH |
reponame_str |
Revista UDH - Revista Peruana de Ciencias de la Salud |
collection |
Revista UDH - Revista Peruana de Ciencias de la Salud |
instname_str |
Universidad de Huánuco |
instacron_str |
UDH |
institution |
UDH |
repository.name.fl_str_mv |
-
|
repository.mail.fl_str_mv |
mail@mail.com |
_version_ |
1700205314440167424 |
spelling |
Quality of the design of removable partial dentures in working modelsCalidad del diseño de prótesis parcial removible en modelos de trabajoQualidade do desenho da prótese parcial removível em modelos de trabalhoCalzada Gonzales, NancyOrtega-Buitron, MarisolhumanosDentadura parcial RetirableLaboratorios DentalesxLaboratorios DentalesArco dentalEstudios prospectivosEstudios de muestreoDiseño de la investigaciónDentistasPersonal de laboratorioObjective. was to determine the quality of removable partial denture (RP) design in working models performed in Huánuco as of 2017 according to the years of experience of the professionals. Methods. This is a descriptive level, cross-sectional, basic and prospective study. Under a quantitative approach, 280 working models for the fabrication of removable partial dentures were included in the study. Samples were collected in dental laboratories in the city of Huánuco. The components of the PPR design were observed for each sample. Descriptive statistics were applied. Results. 73 (91.3 %) did not carry out the shipping order (instructions from the dental professional about the design that the PPR should have), delegating the choice of the design to the dental laboratory technician and in a lower percentage did the instructions for the elaboration of the PPR 7 (8.8 %), 51 working models were upper dental arches and in a lower percentage, 29 (36.3 %) were the lower dental arches. The design quality of the removable partial denture bases in working models was acceptable in a total of 46 models. Conclusion. The quality of the design of the removable partial dentures was incorrect in a high percentage of cases; the components that make up the prosthesis did not comply with the ideal characteristics. 22.86 % of the dentists sent the working models with the design for the fabrication of the removable partial prosthesis.Objetivo. fue determinar la calidad del diseño de la prótesis parcial removible (PPR) en modelos de trabajo realizados en Huánuco al 2017 de acuerdo a los años de experiencia de los profesionales. Métodos. Se trata de un estudio de nivel descriptivo, de tipo transversal, básico y prospectivo. Bajo un enfoque cuantitativo, fueron incluidos en el estudio 280 modelos de trabajo para la confección de las prótesis parciales removibles. Se recolectaron las muestras en los laboratorios dentales de la ciudad de Huánuco. De cada muestra se observó los componentes del diseño de PPR. Se aplicó la estadística descriptiva. Resultados. 73 (91,3 %) no realizaron orden de envío (instrucciones del profesional odontólogo acerca del diseño que debe tener la PPR), delegando la elección del diseño al técnico del laboratorio dental y en un menor porcentaje lo hicieron las instrucciones para la elaboración de la PPR 7 (8,8 %), 51 modelos de trabajo fueron arcos dentarios superiores y en un menor porcentaje, 29 (36,3 %) fueron los arcos dentarios inferiores. La calidad de diseño de las bases de las prótesis parciales removibles en modelos de trabajo, fue aceptable un total de 46 modelos. Conclusión. La calidad del diseño de las prótesis parciales removibles en un alto porcentaje fue incorrecta, no cumplen con características ideales los componentes que lo conforman. El 22,86 % de los odontólogos envían los modelos de trabajo con diseño para la confección de la prótesis parcial removible. Objetivo. era determinar a qualidade do design da prótese parcial removível (RP) nos modelos de trabalho feitos em Huánuco até 2017, de acordo com os anos de experiência dos profissionais. Métodos. Este é um estudo descritivo de nível, transversal, básico e prospectivo. Sob uma abordagem quantitativa, 280 modelos de trabalho para a fabricação de próteses parciais removíveis foram incluídos no estudo. As amostras foram coletadas em laboratórios odontológicos na cidade de Huánuco. Os componentes do projeto do PPR foram observados para cada amostra. Foram aplicadas estatísticas descritivas. Resultados. 73 (91,3%) não realizou a ordem de envio (instruções do profissional odontológico sobre o projeto que o PPR deveria ter), delegando a escolha do projeto ao técnico de laboratório dentário e em uma porcentagem inferior, 7 (8,8%) fez as instruções para a elaboração do PPR, 51 modelos de trabalho eram arcos dentários superiores e em uma porcentagem inferior, 29 (36,3%) eram arcos dentários inferiores. A qualidade do projeto das bases de dentadura parcial removíveis em modelos de trabalho foi aceitável em um total de 46 modelos. Conclusão. A qualidade do projeto da prótese parcial removível foi incorreta em uma alta porcentagem de casos, cujos componentes não cumprem com as características ideais. 22,86 % dos dentistas enviaram os modelos de trabalho com o desenho para a fabricação da prótese parcial removível.UNIVERSIDAD DE HUÁNUCO2019-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlhttp://revistas.udh.edu.pe/index.php/RPCS/article/view/1910.37711/rpcs.2019.1.2.19Revista Peruana de Ciencias de la Salud; Vol. 1 Núm. 2 (2019): Revista Peruana de Ciencias de la Salud (Abr - Jun); 69-74Revista Peruana de Ciencias de la Salud; Vol. 1 Núm. 2 (2019): Revista Peruana de Ciencias de la Salud (Abr - Jun); 69-74Revista Peruana de Ciencias de la Salud; Vol. 1 Núm. 2 (2019): Revista Peruana de Ciencias de la Salud (Abr - Jun); 69-742707-69542707-6946reponame:Revista UDH - Revista Peruana de Ciencias de la Saludinstname:Universidad de Huánucoinstacron:UDHspahttp://revistas.udh.edu.pe/index.php/RPCS/article/view/19/37http://revistas.udh.edu.pe/index.php/RPCS/article/view/19/84info:eu-repo/semantics/openAccess2021-05-19T16:35:12Zmail@mail.com - |
score |
13.882472 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).