Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order

Descripción del Articulo

Experimental results are presented adaptive control with reference model of a plant according to your previously made identification can be represented as a first order system. Is chosen as the reference model also one of the first order with unity gain. Adaptive controller analysis is performed, ju...

Descripción completa

Detalles Bibliográficos
Autor: Vargas Tamani, Bruno
Formato: artículo
Fecha de Publicación:2014
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revista UNMSM - Industrial Data
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/12051
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/12051
Nivel de acceso:acceso abierto
Materia:adaptive control
model reference gradient error
overshoot
settling time
control adaptativo
gradiente del error
modelo de referencia
sobreimpulso
tiempo de establecimiento
id 1810-9993_ff40e92ae0c7c304752eedc9b1e23bf0
oai_identifier_str oai:ojs.csi.unmsm:article/12051
network_acronym_str 1810-9993
repository_id_str .
network_name_str Revista UNMSM - Industrial Data
spelling Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First OrderEfecto en la respuesta temporal del parámetro ajustable del control adaptativo con modelo de referencia de primer ordenVargas Tamani, Brunoadaptive controlmodel reference gradient errorovershootsettling timecontrol adaptativogradiente del errormodelo de referenciasobreimpulsotiempo de establecimientoExperimental results are presented adaptive control with reference model of a plant according to your previously made identification can be represented as a first order system. Is chosen as the reference model also one of the first order with unity gain. Adaptive controller analysis is performed, justifying its performance in closed loop depends on the proper choice of a scale parameter adjustable. The controller is implemented and temporary plant responses to step inputs for different kinds of adjustable parameter values are recorded.Se presentan los resultados experimentales del control adaptativo con modelo de referencia, de una planta que de acuerdo a su identificación previamente realizada se puede representar como un sistema de primer orden. Se elige como modelo de referencia también uno de primer orden con ganancia unitaria. Se realiza el análisis del controlador adaptativo, justificándose que su desempeño en lazo cerrado dependerá de la elección adecuada de un parámetro escalar ajustable. Se implementa el controlador y se registran las respuestas temporales de la planta para entradas tipo escalón para diferentes valores del parámetro ajustable.Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos2014-12-20info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/1205110.15381/idata.v17i2.12051Industrial Data; Vol. 17 Núm. 2 (2014); 81-90Industrial Data; Vol 17 No 2 (2014); 81-901810-99931560-9146reponame:Revista UNMSM - Industrial Datainstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/12051/10767Derechos de autor 2014 Bruno Vargas Tamanihttp://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2021-06-01T17:26:37Zmail@mail.com -
dc.title.none.fl_str_mv Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
Efecto en la respuesta temporal del parámetro ajustable del control adaptativo con modelo de referencia de primer orden
title Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
spellingShingle Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
Vargas Tamani, Bruno
adaptive control
model reference gradient error
overshoot
settling time
control adaptativo
gradiente del error
modelo de referencia
sobreimpulso
tiempo de establecimiento
title_short Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
title_full Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
title_fullStr Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
title_full_unstemmed Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
title_sort Effect on Temporal Response Adjustable Parameter Adaptive Control with Reference Model First Order
dc.creator.none.fl_str_mv Vargas Tamani, Bruno
author Vargas Tamani, Bruno
author_facet Vargas Tamani, Bruno
author_role author
dc.subject.none.fl_str_mv adaptive control
model reference gradient error
overshoot
settling time
control adaptativo
gradiente del error
modelo de referencia
sobreimpulso
tiempo de establecimiento
topic adaptive control
model reference gradient error
overshoot
settling time
control adaptativo
gradiente del error
modelo de referencia
sobreimpulso
tiempo de establecimiento
dc.description.none.fl_txt_mv Experimental results are presented adaptive control with reference model of a plant according to your previously made identification can be represented as a first order system. Is chosen as the reference model also one of the first order with unity gain. Adaptive controller analysis is performed, justifying its performance in closed loop depends on the proper choice of a scale parameter adjustable. The controller is implemented and temporary plant responses to step inputs for different kinds of adjustable parameter values are recorded.
Se presentan los resultados experimentales del control adaptativo con modelo de referencia, de una planta que de acuerdo a su identificación previamente realizada se puede representar como un sistema de primer orden. Se elige como modelo de referencia también uno de primer orden con ganancia unitaria. Se realiza el análisis del controlador adaptativo, justificándose que su desempeño en lazo cerrado dependerá de la elección adecuada de un parámetro escalar ajustable. Se implementa el controlador y se registran las respuestas temporales de la planta para entradas tipo escalón para diferentes valores del parámetro ajustable.
description Experimental results are presented adaptive control with reference model of a plant according to your previously made identification can be represented as a first order system. Is chosen as the reference model also one of the first order with unity gain. Adaptive controller analysis is performed, justifying its performance in closed loop depends on the proper choice of a scale parameter adjustable. The controller is implemented and temporary plant responses to step inputs for different kinds of adjustable parameter values are recorded.
publishDate 2014
dc.date.none.fl_str_mv 2014-12-20
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/12051
10.15381/idata.v17i2.12051
url https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/12051
identifier_str_mv 10.15381/idata.v17i2.12051
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/idata/article/view/12051/10767
dc.rights.none.fl_str_mv Derechos de autor 2014 Bruno Vargas Tamani
http://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2014 Bruno Vargas Tamani
http://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos
publisher.none.fl_str_mv Facultad de Ingeniería Industrial, Universidad Nacional Mayor de San Marcos
dc.source.none.fl_str_mv Industrial Data; Vol. 17 Núm. 2 (2014); 81-90
Industrial Data; Vol 17 No 2 (2014); 81-90
1810-9993
1560-9146
reponame:Revista UNMSM - Industrial Data
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
reponame_str Revista UNMSM - Industrial Data
collection Revista UNMSM - Industrial Data
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701386358987161600
score 13.888049
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).