Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte

Descripción del Articulo

Electrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment...

Descripción completa

Detalles Bibliográficos
Autores: Cuba Tello, María Vanessa, Alcocer Meneses, Paul, Pacheco Ortíz, Mariano
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revista UNMSM - IIGEO
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/17287
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287
Nivel de acceso:acceso abierto
Materia:Gray water
electrocoagulation (EC)
electrode
electrolysis
Taguchi
Agua gris
electrocoagulación (EC)
electrodo
electrólisis
id 1682-3087_dd5d009e4298ca4972b9fcca9550bf45
oai_identifier_str oai:ojs.csi.unmsm:article/17287
network_acronym_str 1682-3087
network_name_str Revista UNMSM - IIGEO
spelling Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate VitarteTratamiento de agua residual procedente de lavadoras por el método de electrocoagulación para la reutilización en riego de vegetales – Ate VitarteCuba Tello, María VanessaAlcocer Meneses, PaulPacheco Ortíz, MarianoGray waterelectrocoagulation (EC)electrodeelectrolysisTaguchiAgua griselectrocoagulación (EC)electrodoelectrólisisTaguchiElectrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment of wastewater from washing machines to be reused in vegetable irrigation, analyzed regularly was verified. Four factors were analyzed: intensity, time, distance and pH; with three levels for each factor. To optimize the electrocoagulation process on the design factors, the experiments were carried out according to the Taguchi method. The analysis of variance (ANOVA) was performed to see the effect of the variables on the removal of turbidity and other physicochemical parameters. The results showed that the parameters with the greatest influence on the removal of turbidity were time and intensity compared to the others. The optimization of the factors on the high removal of the physicochemical parameters was obtained at the levels of intensity 5 Amps, time of 15 minutes, distance of 2 centimeters and pH 7.5, with a removal of 99.02% in turbidity, 90.83% in COD Y 95.93% in SST, with which the treated effluent is in the permissible range for use in vegetable irrigation.La electrocoagulación (EC) en los últimos años está llamando la atención para la eliminación de diferentes contaminantes presentes en diversos efluentes. A través de este trabajo, se verificó la viabilidad de utilizar la técnica de electrocoagulación como una alternativa ante los procesos químicos convencionales, en el tratamiento del agua residual de lavadoras para ser reutilizado en riego de vegetales. Analizadas regularmente. Se analizaron cuatro factores: intensidad, tiempo, distancia y pH; con tres niveles para cada factor. Para optimizar el proceso de electrocoagulación sobre los factores de diseño, se realizaron experimentos de acuerdo al método de Taguchi. Se realizó el análisis de varianza (ANOVA) para ver el efecto de los variables sobre la remoción de la turbiedad y otros parámetros fisicoquímicos. Los resultados arrojaron que los parámetros de mayor influencia en la remoción de la turbiedad fueron tiempo e intensidad a comparación de los demás. La optimización de los factores sobre la alta remoción de los parámetros fisicoquímicos se obtuvo a los niveles de intensidad 5 Amperios, 15 minutos, 2 centímetros y pH 7.5, con una remoción de 99.02% turbiedad, 90.83% DQO y 95.93% SST, el efluente tratado se encuentra en el rango permisible para su uso en riego de vegetales.Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica2019-12-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/1728710.15381/iigeo.v1i1.17287Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 22 No 44 (2019); 65-74Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 22 Núm. 44 (2019); 65-741682-30871561-088810.15381/iigeo.v22i44reponame:Revista UNMSM - IIGEOinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287/14543Derechos de autor 2019 María Vanessa Cuba Tello, Paul Alcocer Meneses, Mariano Pacheco Ortízhttp://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2020-03-17T18:25:40Zmail@mail.com -
dc.title.none.fl_str_mv Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
Tratamiento de agua residual procedente de lavadoras por el método de electrocoagulación para la reutilización en riego de vegetales – Ate Vitarte
title Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
spellingShingle Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
Cuba Tello, María Vanessa
Gray water
electrocoagulation (EC)
electrode
electrolysis
Taguchi
Agua gris
electrocoagulación (EC)
electrodo
electrólisis
Taguchi
title_short Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
title_full Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
title_fullStr Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
title_full_unstemmed Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
title_sort Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
dc.creator.none.fl_str_mv Cuba Tello, María Vanessa
Alcocer Meneses, Paul
Pacheco Ortíz, Mariano
author Cuba Tello, María Vanessa
author_facet Cuba Tello, María Vanessa
Alcocer Meneses, Paul
Pacheco Ortíz, Mariano
author_role author
author2 Alcocer Meneses, Paul
Pacheco Ortíz, Mariano
author2_role author
author
dc.subject.none.fl_str_mv Gray water
electrocoagulation (EC)
electrode
electrolysis
Taguchi
Agua gris
electrocoagulación (EC)
electrodo
electrólisis
Taguchi
topic Gray water
electrocoagulation (EC)
electrode
electrolysis
Taguchi
Agua gris
electrocoagulación (EC)
electrodo
electrólisis
Taguchi
dc.description.none.fl_txt_mv Electrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment of wastewater from washing machines to be reused in vegetable irrigation, analyzed regularly was verified. Four factors were analyzed: intensity, time, distance and pH; with three levels for each factor. To optimize the electrocoagulation process on the design factors, the experiments were carried out according to the Taguchi method. The analysis of variance (ANOVA) was performed to see the effect of the variables on the removal of turbidity and other physicochemical parameters. The results showed that the parameters with the greatest influence on the removal of turbidity were time and intensity compared to the others. The optimization of the factors on the high removal of the physicochemical parameters was obtained at the levels of intensity 5 Amps, time of 15 minutes, distance of 2 centimeters and pH 7.5, with a removal of 99.02% in turbidity, 90.83% in COD Y 95.93% in SST, with which the treated effluent is in the permissible range for use in vegetable irrigation.
La electrocoagulación (EC) en los últimos años está llamando la atención para la eliminación de diferentes contaminantes presentes en diversos efluentes. A través de este trabajo, se verificó la viabilidad de utilizar la técnica de electrocoagulación como una alternativa ante los procesos químicos convencionales, en el tratamiento del agua residual de lavadoras para ser reutilizado en riego de vegetales. Analizadas regularmente. Se analizaron cuatro factores: intensidad, tiempo, distancia y pH; con tres niveles para cada factor. Para optimizar el proceso de electrocoagulación sobre los factores de diseño, se realizaron experimentos de acuerdo al método de Taguchi. Se realizó el análisis de varianza (ANOVA) para ver el efecto de los variables sobre la remoción de la turbiedad y otros parámetros fisicoquímicos. Los resultados arrojaron que los parámetros de mayor influencia en la remoción de la turbiedad fueron tiempo e intensidad a comparación de los demás. La optimización de los factores sobre la alta remoción de los parámetros fisicoquímicos se obtuvo a los niveles de intensidad 5 Amperios, 15 minutos, 2 centímetros y pH 7.5, con una remoción de 99.02% turbiedad, 90.83% DQO y 95.93% SST, el efluente tratado se encuentra en el rango permisible para su uso en riego de vegetales.
description Electrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment of wastewater from washing machines to be reused in vegetable irrigation, analyzed regularly was verified. Four factors were analyzed: intensity, time, distance and pH; with three levels for each factor. To optimize the electrocoagulation process on the design factors, the experiments were carried out according to the Taguchi method. The analysis of variance (ANOVA) was performed to see the effect of the variables on the removal of turbidity and other physicochemical parameters. The results showed that the parameters with the greatest influence on the removal of turbidity were time and intensity compared to the others. The optimization of the factors on the high removal of the physicochemical parameters was obtained at the levels of intensity 5 Amps, time of 15 minutes, distance of 2 centimeters and pH 7.5, with a removal of 99.02% in turbidity, 90.83% in COD Y 95.93% in SST, with which the treated effluent is in the permissible range for use in vegetable irrigation.
publishDate 2019
dc.date.none.fl_str_mv 2019-12-15
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287
10.15381/iigeo.v1i1.17287
url https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287
identifier_str_mv 10.15381/iigeo.v1i1.17287
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287/14543
dc.rights.none.fl_str_mv Derechos de autor 2019 María Vanessa Cuba Tello, Paul Alcocer Meneses, Mariano Pacheco Ortíz
http://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2019 María Vanessa Cuba Tello, Paul Alcocer Meneses, Mariano Pacheco Ortíz
http://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica
publisher.none.fl_str_mv Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica
dc.source.none.fl_str_mv Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 22 No 44 (2019); 65-74
Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 22 Núm. 44 (2019); 65-74
1682-3087
1561-0888
10.15381/iigeo.v22i44
reponame:Revista UNMSM - IIGEO
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
reponame_str Revista UNMSM - IIGEO
collection Revista UNMSM - IIGEO
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1684466182421217280
score 13.887938
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).