Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte
Descripción del Articulo
Electrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revista UNMSM - IIGEO |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/17287 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287 |
Nivel de acceso: | acceso abierto |
Materia: | Gray water electrocoagulation (EC) electrode electrolysis Taguchi Agua gris electrocoagulación (EC) electrodo electrólisis |
id |
1682-3087_dd5d009e4298ca4972b9fcca9550bf45 |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/17287 |
network_acronym_str |
1682-3087 |
network_name_str |
Revista UNMSM - IIGEO |
spelling |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate VitarteTratamiento de agua residual procedente de lavadoras por el método de electrocoagulación para la reutilización en riego de vegetales – Ate VitarteCuba Tello, María VanessaAlcocer Meneses, PaulPacheco Ortíz, MarianoGray waterelectrocoagulation (EC)electrodeelectrolysisTaguchiAgua griselectrocoagulación (EC)electrodoelectrólisisTaguchiElectrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment of wastewater from washing machines to be reused in vegetable irrigation, analyzed regularly was verified. Four factors were analyzed: intensity, time, distance and pH; with three levels for each factor. To optimize the electrocoagulation process on the design factors, the experiments were carried out according to the Taguchi method. The analysis of variance (ANOVA) was performed to see the effect of the variables on the removal of turbidity and other physicochemical parameters. The results showed that the parameters with the greatest influence on the removal of turbidity were time and intensity compared to the others. The optimization of the factors on the high removal of the physicochemical parameters was obtained at the levels of intensity 5 Amps, time of 15 minutes, distance of 2 centimeters and pH 7.5, with a removal of 99.02% in turbidity, 90.83% in COD Y 95.93% in SST, with which the treated effluent is in the permissible range for use in vegetable irrigation.La electrocoagulación (EC) en los últimos años está llamando la atención para la eliminación de diferentes contaminantes presentes en diversos efluentes. A través de este trabajo, se verificó la viabilidad de utilizar la técnica de electrocoagulación como una alternativa ante los procesos químicos convencionales, en el tratamiento del agua residual de lavadoras para ser reutilizado en riego de vegetales. Analizadas regularmente. Se analizaron cuatro factores: intensidad, tiempo, distancia y pH; con tres niveles para cada factor. Para optimizar el proceso de electrocoagulación sobre los factores de diseño, se realizaron experimentos de acuerdo al método de Taguchi. Se realizó el análisis de varianza (ANOVA) para ver el efecto de los variables sobre la remoción de la turbiedad y otros parámetros fisicoquímicos. Los resultados arrojaron que los parámetros de mayor influencia en la remoción de la turbiedad fueron tiempo e intensidad a comparación de los demás. La optimización de los factores sobre la alta remoción de los parámetros fisicoquímicos se obtuvo a los niveles de intensidad 5 Amperios, 15 minutos, 2 centímetros y pH 7.5, con una remoción de 99.02% turbiedad, 90.83% DQO y 95.93% SST, el efluente tratado se encuentra en el rango permisible para su uso en riego de vegetales.Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica2019-12-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/1728710.15381/iigeo.v1i1.17287Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 22 No 44 (2019); 65-74Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 22 Núm. 44 (2019); 65-741682-30871561-088810.15381/iigeo.v22i44reponame:Revista UNMSM - IIGEOinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287/14543Derechos de autor 2019 María Vanessa Cuba Tello, Paul Alcocer Meneses, Mariano Pacheco Ortízhttp://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2020-03-17T18:25:40Zmail@mail.com - |
dc.title.none.fl_str_mv |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte Tratamiento de agua residual procedente de lavadoras por el método de electrocoagulación para la reutilización en riego de vegetales – Ate Vitarte |
title |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte |
spellingShingle |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte Cuba Tello, María Vanessa Gray water electrocoagulation (EC) electrode electrolysis Taguchi Agua gris electrocoagulación (EC) electrodo electrólisis Taguchi |
title_short |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte |
title_full |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte |
title_fullStr |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte |
title_full_unstemmed |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte |
title_sort |
Wastewater treatment from washing machines by the method of electrocoagulation for the reuse in irrigation of vegetables - Ate Vitarte |
dc.creator.none.fl_str_mv |
Cuba Tello, María Vanessa Alcocer Meneses, Paul Pacheco Ortíz, Mariano |
author |
Cuba Tello, María Vanessa |
author_facet |
Cuba Tello, María Vanessa Alcocer Meneses, Paul Pacheco Ortíz, Mariano |
author_role |
author |
author2 |
Alcocer Meneses, Paul Pacheco Ortíz, Mariano |
author2_role |
author author |
dc.subject.none.fl_str_mv |
Gray water electrocoagulation (EC) electrode electrolysis Taguchi Agua gris electrocoagulación (EC) electrodo electrólisis Taguchi |
topic |
Gray water electrocoagulation (EC) electrode electrolysis Taguchi Agua gris electrocoagulación (EC) electrodo electrólisis Taguchi |
dc.description.none.fl_txt_mv |
Electrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment of wastewater from washing machines to be reused in vegetable irrigation, analyzed regularly was verified. Four factors were analyzed: intensity, time, distance and pH; with three levels for each factor. To optimize the electrocoagulation process on the design factors, the experiments were carried out according to the Taguchi method. The analysis of variance (ANOVA) was performed to see the effect of the variables on the removal of turbidity and other physicochemical parameters. The results showed that the parameters with the greatest influence on the removal of turbidity were time and intensity compared to the others. The optimization of the factors on the high removal of the physicochemical parameters was obtained at the levels of intensity 5 Amps, time of 15 minutes, distance of 2 centimeters and pH 7.5, with a removal of 99.02% in turbidity, 90.83% in COD Y 95.93% in SST, with which the treated effluent is in the permissible range for use in vegetable irrigation. La electrocoagulación (EC) en los últimos años está llamando la atención para la eliminación de diferentes contaminantes presentes en diversos efluentes. A través de este trabajo, se verificó la viabilidad de utilizar la técnica de electrocoagulación como una alternativa ante los procesos químicos convencionales, en el tratamiento del agua residual de lavadoras para ser reutilizado en riego de vegetales. Analizadas regularmente. Se analizaron cuatro factores: intensidad, tiempo, distancia y pH; con tres niveles para cada factor. Para optimizar el proceso de electrocoagulación sobre los factores de diseño, se realizaron experimentos de acuerdo al método de Taguchi. Se realizó el análisis de varianza (ANOVA) para ver el efecto de los variables sobre la remoción de la turbiedad y otros parámetros fisicoquímicos. Los resultados arrojaron que los parámetros de mayor influencia en la remoción de la turbiedad fueron tiempo e intensidad a comparación de los demás. La optimización de los factores sobre la alta remoción de los parámetros fisicoquímicos se obtuvo a los niveles de intensidad 5 Amperios, 15 minutos, 2 centímetros y pH 7.5, con una remoción de 99.02% turbiedad, 90.83% DQO y 95.93% SST, el efluente tratado se encuentra en el rango permisible para su uso en riego de vegetales. |
description |
Electrocoagulation (EC) in recent years is calling the growing attention for the elimination of different contaminants present in the various effluents. Through this work, the feasibility of using the electrocoagulation technique as an alternative to conventional chemical processes in the treatment of wastewater from washing machines to be reused in vegetable irrigation, analyzed regularly was verified. Four factors were analyzed: intensity, time, distance and pH; with three levels for each factor. To optimize the electrocoagulation process on the design factors, the experiments were carried out according to the Taguchi method. The analysis of variance (ANOVA) was performed to see the effect of the variables on the removal of turbidity and other physicochemical parameters. The results showed that the parameters with the greatest influence on the removal of turbidity were time and intensity compared to the others. The optimization of the factors on the high removal of the physicochemical parameters was obtained at the levels of intensity 5 Amps, time of 15 minutes, distance of 2 centimeters and pH 7.5, with a removal of 99.02% in turbidity, 90.83% in COD Y 95.93% in SST, with which the treated effluent is in the permissible range for use in vegetable irrigation. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-12-15 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287 10.15381/iigeo.v1i1.17287 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287 |
identifier_str_mv |
10.15381/iigeo.v1i1.17287 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/17287/14543 |
dc.rights.none.fl_str_mv |
Derechos de autor 2019 María Vanessa Cuba Tello, Paul Alcocer Meneses, Mariano Pacheco Ortíz http://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2019 María Vanessa Cuba Tello, Paul Alcocer Meneses, Mariano Pacheco Ortíz http://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica |
publisher.none.fl_str_mv |
Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica |
dc.source.none.fl_str_mv |
Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 22 No 44 (2019); 65-74 Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 22 Núm. 44 (2019); 65-74 1682-3087 1561-0888 10.15381/iigeo.v22i44 reponame:Revista UNMSM - IIGEO instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
reponame_str |
Revista UNMSM - IIGEO |
collection |
Revista UNMSM - IIGEO |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
repository.name.fl_str_mv |
-
|
repository.mail.fl_str_mv |
mail@mail.com |
_version_ |
1684466182421217280 |
score |
13.887938 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).