Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective
Descripción del Articulo
It seeks to develop a mathematical model that predicts the decay of the temperature of the liquid steel spoon 15 TM. The shots were made in temperature castings production, measuring the temperature after excoriated and before emptying the holding furnace, the time was also recorded between the two...
Autor: | |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2012 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revista UNMSM - IIGEO |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/3441 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/3441 |
Nivel de acceso: | acceso abierto |
Materia: | modeling liquid steel casting decay temperature modelamiento acero líquido colada decaimiento de temperatura |
id |
1682-3087_493b560f026c0b0e8fd66df34b497cc4 |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/3441 |
network_acronym_str |
1682-3087 |
network_name_str |
Revista UNMSM - IIGEO |
spelling |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspectiveModelo empírico del enfriamiento del acero líquido en cuchara de 15TM: Una perspectiva industrialMancha Gonzales, Salvatoremodelingliquid steel castingdecay temperaturemodelamientoacero líquidocoladadecaimiento de temperaturaIt seeks to develop a mathematical model that predicts the decay of the temperature of the liquid steel spoon 15 TM. The shots were made in temperature castings production, measuring the temperature after excoriated and before emptying the holding furnace, the time was also recorded between the two jacks temperature. Then the data obtained was analyzed to obtain the parameters of the particular model (K and T0). The derivation of the model was obtained from an Ordinary Differential Equation (ODE) homogeneous. Prognostic value of the model obtained with new values measured temperature was compared. To make the prognosis of two different values of temperature T0, one with a constant value of T0, as shown in the model found, and another with T0, a variable that was numerically equal to the temperature after excoriated were used, both forecasts were compared with various indicators. Which influence the value T0 in the model is determined. Stability parameter K by t-student test for the two sets of data was evaluated and finally the total error of temperature measurement considering the forecast error and the error of the equipment used is estimated.Se busca desarrollar un modelo matemático que pronostique el decaimiento de la temperatura del acero líquido en una cuchara de 15 TM. Las tomas de temperatura se efectuaron en las coladas de producción, midiéndose la temperatura después de escoriado y antes de vaciar al horno de mantenimiento, también se registró el tiempo entre las dos tomas de temperatura. Luego la data obtenida fue analizada hasta obtener los parámetros del modelo particular (K y T0). La deducción del modelo fue obtenida a partir de una Ecuación Diferencial Ordinaria (EDO) homogénea. Se comparo el valor del pronóstico del modelo obtenido con nuevos valores de temperaturas medidas. Para efectuar el pronóstico de temperatura se usaron dos valores distintos de T0 , uno con un valor constante de T0 , tal como se muestra en el modelo hallado, y otro con T0 , variable que era numéricamente igual a la temperatura después de escoriado, ambos pronósticos fueron contrastados con varios indicadores. Del cual se determinó la influencia del valor T0 en el modelo. Se evaluó la estabilidad del parámetro K mediante prueba t-student para las dos series de datos y por último se estima el error total de medición de temperatura considerando el error del pronóstico y el error del equipo empleado.Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica2012-12-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/344110.15381/iigeo.v15i30.3441Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 15 No 30 (2012); 85-91Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 15 Núm. 30 (2012); 85-911682-30871561-0888reponame:Revista UNMSM - IIGEOinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/3441/2845Derechos de autor 2012 Salvatore Mancha Gonzaleshttp://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2020-03-10T18:26:37Zmail@mail.com - |
dc.title.none.fl_str_mv |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective Modelo empírico del enfriamiento del acero líquido en cuchara de 15TM: Una perspectiva industrial |
title |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective |
spellingShingle |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective Mancha Gonzales, Salvatore modeling liquid steel casting decay temperature modelamiento acero líquido colada decaimiento de temperatura |
title_short |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective |
title_full |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective |
title_fullStr |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective |
title_full_unstemmed |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective |
title_sort |
Empirical model of the cooling liquid steel spoon 15TM: an industrial perspective |
dc.creator.none.fl_str_mv |
Mancha Gonzales, Salvatore |
author |
Mancha Gonzales, Salvatore |
author_facet |
Mancha Gonzales, Salvatore |
author_role |
author |
dc.subject.none.fl_str_mv |
modeling liquid steel casting decay temperature modelamiento acero líquido colada decaimiento de temperatura |
topic |
modeling liquid steel casting decay temperature modelamiento acero líquido colada decaimiento de temperatura |
dc.description.none.fl_txt_mv |
It seeks to develop a mathematical model that predicts the decay of the temperature of the liquid steel spoon 15 TM. The shots were made in temperature castings production, measuring the temperature after excoriated and before emptying the holding furnace, the time was also recorded between the two jacks temperature. Then the data obtained was analyzed to obtain the parameters of the particular model (K and T0). The derivation of the model was obtained from an Ordinary Differential Equation (ODE) homogeneous. Prognostic value of the model obtained with new values measured temperature was compared. To make the prognosis of two different values of temperature T0, one with a constant value of T0, as shown in the model found, and another with T0, a variable that was numerically equal to the temperature after excoriated were used, both forecasts were compared with various indicators. Which influence the value T0 in the model is determined. Stability parameter K by t-student test for the two sets of data was evaluated and finally the total error of temperature measurement considering the forecast error and the error of the equipment used is estimated. Se busca desarrollar un modelo matemático que pronostique el decaimiento de la temperatura del acero líquido en una cuchara de 15 TM. Las tomas de temperatura se efectuaron en las coladas de producción, midiéndose la temperatura después de escoriado y antes de vaciar al horno de mantenimiento, también se registró el tiempo entre las dos tomas de temperatura. Luego la data obtenida fue analizada hasta obtener los parámetros del modelo particular (K y T0). La deducción del modelo fue obtenida a partir de una Ecuación Diferencial Ordinaria (EDO) homogénea. Se comparo el valor del pronóstico del modelo obtenido con nuevos valores de temperaturas medidas. Para efectuar el pronóstico de temperatura se usaron dos valores distintos de T0 , uno con un valor constante de T0 , tal como se muestra en el modelo hallado, y otro con T0 , variable que era numéricamente igual a la temperatura después de escoriado, ambos pronósticos fueron contrastados con varios indicadores. Del cual se determinó la influencia del valor T0 en el modelo. Se evaluó la estabilidad del parámetro K mediante prueba t-student para las dos series de datos y por último se estima el error total de medición de temperatura considerando el error del pronóstico y el error del equipo empleado. |
description |
It seeks to develop a mathematical model that predicts the decay of the temperature of the liquid steel spoon 15 TM. The shots were made in temperature castings production, measuring the temperature after excoriated and before emptying the holding furnace, the time was also recorded between the two jacks temperature. Then the data obtained was analyzed to obtain the parameters of the particular model (K and T0). The derivation of the model was obtained from an Ordinary Differential Equation (ODE) homogeneous. Prognostic value of the model obtained with new values measured temperature was compared. To make the prognosis of two different values of temperature T0, one with a constant value of T0, as shown in the model found, and another with T0, a variable that was numerically equal to the temperature after excoriated were used, both forecasts were compared with various indicators. Which influence the value T0 in the model is determined. Stability parameter K by t-student test for the two sets of data was evaluated and finally the total error of temperature measurement considering the forecast error and the error of the equipment used is estimated. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-12-15 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/3441 10.15381/iigeo.v15i30.3441 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/3441 |
identifier_str_mv |
10.15381/iigeo.v15i30.3441 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/3441/2845 |
dc.rights.none.fl_str_mv |
Derechos de autor 2012 Salvatore Mancha Gonzales http://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2012 Salvatore Mancha Gonzales http://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica |
publisher.none.fl_str_mv |
Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica |
dc.source.none.fl_str_mv |
Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 15 No 30 (2012); 85-91 Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 15 Núm. 30 (2012); 85-91 1682-3087 1561-0888 reponame:Revista UNMSM - IIGEO instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
reponame_str |
Revista UNMSM - IIGEO |
collection |
Revista UNMSM - IIGEO |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
repository.name.fl_str_mv |
-
|
repository.mail.fl_str_mv |
mail@mail.com |
_version_ |
1684466180505468928 |
score |
13.887938 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).