Chemical and topographical analysis of the surface of dental implants

Descripción del Articulo

The aim of this study was to analyze the chemical composition and surface topography of commercially pure titanium implants, obtained from three trademarks frequently used in dentistry. There were nine titanium implants of the following systems: As Technology, Neodent and Sistema Nacional de Implant...

Descripción completa

Detalles Bibliográficos
Autores: Muñante Cárdenas, Jose Luis, Landers, Richard
Formato: artículo
Fecha de Publicación:2012
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revista UNMSM - Odontología Sanmarquina
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/2818
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2818
Nivel de acceso:acceso abierto
Materia:dental implants
titanium
chemical analysis
biocompatible materials
implantes dentales
titanio
análisis químico
materiales biocompatibles
id 1609-8617_98540ec789eb474d0d98282d60e6c388
oai_identifier_str oai:ojs.csi.unmsm:article/2818
network_acronym_str 1609-8617
repository_id_str .
network_name_str Revista UNMSM - Odontología Sanmarquina
spelling Chemical and topographical analysis of the surface of dental implantsAnálisis químico y topográfico de la superficie de implantes dentalesMuñante Cárdenas, Jose LuisLanders, Richarddental implantstitaniumchemical analysisbiocompatible materialsimplantes dentalestitanioanálisis químicomateriales biocompatiblesThe aim of this study was to analyze the chemical composition and surface topography of commercially pure titanium implants, obtained from three trademarks frequently used in dentistry. There were nine titanium implants of the following systems: As Technology, Neodent and Sistema Nacional de Implantes. These materials were divided into three groups, with three implants in each group. Photoelectron Spectroscopy Excited by X-ray (XPS) was used to determine the chemical composition, while to characterize the surface topography we used Scanning Electron Microscopy (SEM). Titanium, carbon, silicon and oxygen were identified in all samples analyzed. Other contaminants were: silicon, aluminum, sulfur, lead, phosphorus, calcium, sodium and nitrogen. We identified impurities on the surface of all implants analyzed. We consider necessary to development more studies relating the presence and concentration of these elements with the osseointegration process.El objetivo de este estudio fue analizar la composición química y la topografía superficial de implantes de titanio comercialmente puro, obtenidos de tres marcas comerciales utilizadas actualmente en odontología. Fueron analizados nueve implantes de titanio de los siguientes sistemas: As Technology, Neodent y Sistema Nacional de Implantes. El material fue dividido en tres grupos de tres implantes cada uno. Para determinar la composición química se utilizó la técnica de Espectroscopia de Fotoelectrones Excitada por rayos-X (XPS), mientras que para caracterizar la topografía superficial se utilizó Microscopia Electrónica de Barrido (MEB). Fueron identificados titanio, carbono, silicio y oxígeno en todas las muestras analizadas. Otros elementos contaminantes identificados fueron aluminio, azufre, plomo, fósforo, calcio, sodio y nitrógeno. Fueron identificadas impurezas en la superficie de todos los implantes analizados. Consideramos necesario realizar otros estudios que relacionen la presencia y concentración de estos elementos con el proceso de oseointegración.Universidad Nacional Mayor de San Marcos, Facultad de Odontología2012-07-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/281810.15381/os.v15i1.2818Odontología Sanmarquina; Vol 15 No 1 (2012); 5-9Odontología Sanmarquina; Vol. 15 Núm. 1 (2012); 5-91609-86171560-9111reponame:Revista UNMSM - Odontología Sanmarquinainstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2818/2410Derechos de autor 2012 Jose Luis Muñante Cárdenas, Richard Landershttp://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2021-06-01T17:15:28Zmail@mail.com -
dc.title.none.fl_str_mv Chemical and topographical analysis of the surface of dental implants
Análisis químico y topográfico de la superficie de implantes dentales
title Chemical and topographical analysis of the surface of dental implants
spellingShingle Chemical and topographical analysis of the surface of dental implants
Muñante Cárdenas, Jose Luis
dental implants
titanium
chemical analysis
biocompatible materials
implantes dentales
titanio
análisis químico
materiales biocompatibles
title_short Chemical and topographical analysis of the surface of dental implants
title_full Chemical and topographical analysis of the surface of dental implants
title_fullStr Chemical and topographical analysis of the surface of dental implants
title_full_unstemmed Chemical and topographical analysis of the surface of dental implants
title_sort Chemical and topographical analysis of the surface of dental implants
dc.creator.none.fl_str_mv Muñante Cárdenas, Jose Luis
Landers, Richard
author Muñante Cárdenas, Jose Luis
author_facet Muñante Cárdenas, Jose Luis
Landers, Richard
author_role author
author2 Landers, Richard
author2_role author
dc.subject.none.fl_str_mv dental implants
titanium
chemical analysis
biocompatible materials
implantes dentales
titanio
análisis químico
materiales biocompatibles
topic dental implants
titanium
chemical analysis
biocompatible materials
implantes dentales
titanio
análisis químico
materiales biocompatibles
dc.description.none.fl_txt_mv The aim of this study was to analyze the chemical composition and surface topography of commercially pure titanium implants, obtained from three trademarks frequently used in dentistry. There were nine titanium implants of the following systems: As Technology, Neodent and Sistema Nacional de Implantes. These materials were divided into three groups, with three implants in each group. Photoelectron Spectroscopy Excited by X-ray (XPS) was used to determine the chemical composition, while to characterize the surface topography we used Scanning Electron Microscopy (SEM). Titanium, carbon, silicon and oxygen were identified in all samples analyzed. Other contaminants were: silicon, aluminum, sulfur, lead, phosphorus, calcium, sodium and nitrogen. We identified impurities on the surface of all implants analyzed. We consider necessary to development more studies relating the presence and concentration of these elements with the osseointegration process.
El objetivo de este estudio fue analizar la composición química y la topografía superficial de implantes de titanio comercialmente puro, obtenidos de tres marcas comerciales utilizadas actualmente en odontología. Fueron analizados nueve implantes de titanio de los siguientes sistemas: As Technology, Neodent y Sistema Nacional de Implantes. El material fue dividido en tres grupos de tres implantes cada uno. Para determinar la composición química se utilizó la técnica de Espectroscopia de Fotoelectrones Excitada por rayos-X (XPS), mientras que para caracterizar la topografía superficial se utilizó Microscopia Electrónica de Barrido (MEB). Fueron identificados titanio, carbono, silicio y oxígeno en todas las muestras analizadas. Otros elementos contaminantes identificados fueron aluminio, azufre, plomo, fósforo, calcio, sodio y nitrógeno. Fueron identificadas impurezas en la superficie de todos los implantes analizados. Consideramos necesario realizar otros estudios que relacionen la presencia y concentración de estos elementos con el proceso de oseointegración.
description The aim of this study was to analyze the chemical composition and surface topography of commercially pure titanium implants, obtained from three trademarks frequently used in dentistry. There were nine titanium implants of the following systems: As Technology, Neodent and Sistema Nacional de Implantes. These materials were divided into three groups, with three implants in each group. Photoelectron Spectroscopy Excited by X-ray (XPS) was used to determine the chemical composition, while to characterize the surface topography we used Scanning Electron Microscopy (SEM). Titanium, carbon, silicon and oxygen were identified in all samples analyzed. Other contaminants were: silicon, aluminum, sulfur, lead, phosphorus, calcium, sodium and nitrogen. We identified impurities on the surface of all implants analyzed. We consider necessary to development more studies relating the presence and concentration of these elements with the osseointegration process.
publishDate 2012
dc.date.none.fl_str_mv 2012-07-16
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2818
10.15381/os.v15i1.2818
url https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2818
identifier_str_mv 10.15381/os.v15i1.2818
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/2818/2410
dc.rights.none.fl_str_mv Derechos de autor 2012 Jose Luis Muñante Cárdenas, Richard Landers
http://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2012 Jose Luis Muñante Cárdenas, Richard Landers
http://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Odontología
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Odontología
dc.source.none.fl_str_mv Odontología Sanmarquina; Vol 15 No 1 (2012); 5-9
Odontología Sanmarquina; Vol. 15 Núm. 1 (2012); 5-9
1609-8617
1560-9111
reponame:Revista UNMSM - Odontología Sanmarquina
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
reponame_str Revista UNMSM - Odontología Sanmarquina
collection Revista UNMSM - Odontología Sanmarquina
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1701385727756992512
score 13.982926
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).