automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts
Descripción del Articulo
The present work was centred on the study of potassium ethylxanthate, EtX-K+, which displays a remarkable selectivity and is widely employed in the treatment of sulphide ore. It was synthesised in our laboratory and its characterisation was performed, alongside with purity assessment, by analytical...
Autor: | |
---|---|
Formato: | artículo |
Fecha de Publicación: | 1998 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revista UNMSM - Revista Peruana de Química e Ingeniería Química |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/4111 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4111 |
Nivel de acceso: | acceso abierto |
Materia: | xanthate ore analytical flow xantato mineral analítico flujo |
id |
1609-7599_4e61a28f0d56c175982de8d87c1fdd4f |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/4111 |
network_acronym_str |
1609-7599 |
repository_id_str |
. |
network_name_str |
Revista UNMSM - Revista Peruana de Química e Ingeniería Química |
dc.title.none.fl_str_mv |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts METODOLOGIAS ANALITICAS E AUTOMATIZADAS PARA DETERMINACAO DE COLETORES DE FLOTAQAO " XANTATOS" E SUBPRODUTOS METODOLOGIAS ANALITICAS E AUTOMATIZADAS PARA DETERMINACAO DE COLETORES DE FLOTAQAO " XANTATOS" E SUBPRODUTOS |
title |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts |
spellingShingle |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts Hidalgo Falla, P. xanthate ore analytical flow xantato mineral analítico flujo xantato mineral analítico flujo |
title_short |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts |
title_full |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts |
title_fullStr |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts |
title_full_unstemmed |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts |
title_sort |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproducts |
dc.creator.none.fl_str_mv |
Hidalgo Falla, P. |
author |
Hidalgo Falla, P. |
author_facet |
Hidalgo Falla, P. |
author_role |
author |
dc.subject.none.fl_str_mv |
xanthate ore analytical flow xantato mineral analítico flujo xantato mineral analítico flujo |
topic |
xanthate ore analytical flow xantato mineral analítico flujo xantato mineral analítico flujo |
dc.description.none.fl_txt_mv |
The present work was centred on the study of potassium ethylxanthate, EtX-K+, which displays a remarkable selectivity and is widely employed in the treatment of sulphide ore. It was synthesised in our laboratory and its characterisation was performed, alongside with purity assessment, by analytical assays (IR,UV) as well as by decomposition studies. In particular, we aimed to develop the polarography procedure: DC(tast) method coupled with a modern dropping mercury electrode. (SMDE) for the determination of EtX-K+, enabled us to obtain defined and reproducible anodic waves. The investigation was carried out in the presence of NaOH as a supporting electrolyte at pH 12.6 within a broad concentration range (2x10^(-6)-1x10^(-4) M). In a following stage, a flow injection analysis (FIA) system with amperometric detection with wall-jet type cells operated at -0.1 V fixed-potential was implemented. Fia-grams with reasonably reproducible peaks were generated, with a sample throughput capacity of 72 determinations/hour and detection limit is estimate in 0.16 ppm. Neste trabalho enfatizou-se o estudo do etilxantato de potássio, EtX-K+, por ser um reagente bastante seletivo e muito utilizado no tratamento de minerais sulfetados. A síntese foi feita no laboratório e a caracterizaçáo e pureza, além dos estudos de reaçoes de decomposiçáo, foram feitos com auxílio das técnicas analíticas (IR, UV). Procurou-se desenvolver a metodologia polarográfica DC(first) trabalhando com moderno eletrodo de mercúrio de gota estática (SMDE) para a determinaçáo do EtX-K+ , obtiveram-se ondas anódicas definidas e reprodutíveis, usando como eletrólito suporte NaOH, pH 12,6 e numa ampla faixa de concentracáo (2x10^(-6)- 1x10^(-4) M). Na etapa seguinte adaptou-se o método poi aro gráfico a analise por injeçáo em fluxo, FIA, com detecçáo amperométrica; trabalhando a potencial fixo de -0,1V, e usando uma célula tipo "wall-jet" feita no laboratório, foram obtidos fiagramas com picos bastante reprodutíveis; a freqüéncia da amostragem de 72 injeçoes/ hora; o limite de detecçáo foi estimado em O,16 ppm. Neste trabalho enfatizou-se o estudo do etilxantato de potássio, EtX-K+, por ser um reagente bastante seletivo e muito utilizado no tratamento de minerais sulfetados. A síntese foi feita no laboratório e a caracterizaçáo e pureza, além dos estudos de reaçoes de decomposiçáo, foram feitos com auxílio das técnicas analíticas (IR, UV). Procurou-se desenvolver a metodologia polarográfica DC(first) trabalhando com moderno eletrodo de mercúrio de gota estática (SMDE) para a determinaçáo do EtX-K+ , obtiveram-se ondas anódicas definidas e reprodutíveis, usando como eletrólito suporte NaOH, pH 12,6 e numa ampla faixa de concentracáo (2x10^(-6)- 1x10^(-4) M). Na etapa seguinte adaptou-se o método poi aro gráfico a analise por injeçáo em fluxo, FIA, com detecçáo amperométrica; trabalhando a potencial fixo de -0,1V, e usando uma célula tipo "wall-jet" feita no laboratório, foram obtidos fiagramas com picos bastante reprodutíveis; a freqüéncia da amostragem de 72 injeçoes/ hora; o limite de detecçáo foi estimado em O,16 ppm. |
description |
The present work was centred on the study of potassium ethylxanthate, EtX-K+, which displays a remarkable selectivity and is widely employed in the treatment of sulphide ore. It was synthesised in our laboratory and its characterisation was performed, alongside with purity assessment, by analytical assays (IR,UV) as well as by decomposition studies. In particular, we aimed to develop the polarography procedure: DC(tast) method coupled with a modern dropping mercury electrode. (SMDE) for the determination of EtX-K+, enabled us to obtain defined and reproducible anodic waves. The investigation was carried out in the presence of NaOH as a supporting electrolyte at pH 12.6 within a broad concentration range (2x10^(-6)-1x10^(-4) M). In a following stage, a flow injection analysis (FIA) system with amperometric detection with wall-jet type cells operated at -0.1 V fixed-potential was implemented. Fia-grams with reasonably reproducible peaks were generated, with a sample throughput capacity of 72 determinations/hour and detection limit is estimate in 0.16 ppm. |
publishDate |
1998 |
dc.date.none.fl_str_mv |
1998-12-31 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4111 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4111 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4111/3277 |
dc.rights.none.fl_str_mv |
Derechos de autor 1998 P. Hidalgo Falla http://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 1998 P. Hidalgo Falla http://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
dc.source.none.fl_str_mv |
Revista Peruana de Química e Ingeniería Química; Vol 1 No 2 (1998); 169-180 Revista Peruana de Química e Ingeniería Química; Vol. 1 Núm. 2 (1998); 169-180 1609-7599 1726-2208 reponame:Revista UNMSM - Revista Peruana de Química e Ingeniería Química instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
reponame_str |
Revista UNMSM - Revista Peruana de Química e Ingeniería Química |
collection |
Revista UNMSM - Revista Peruana de Química e Ingeniería Química |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
repository.name.fl_str_mv |
-
|
repository.mail.fl_str_mv |
mail@mail.com |
_version_ |
1701389114839924736 |
spelling |
automated analytical methodologies for determining flotation collectors "XANTHATES" and byproductsMETODOLOGIAS ANALITICAS E AUTOMATIZADAS PARA DETERMINACAO DE COLETORES DE FLOTAQAO " XANTATOS" E SUBPRODUTOSMETODOLOGIAS ANALITICAS E AUTOMATIZADAS PARA DETERMINACAO DE COLETORES DE FLOTAQAO " XANTATOS" E SUBPRODUTOSHidalgo Falla, P.xanthateoreanalyticalflowxantatomineralanalíticoflujoxantatomineralanalíticoflujoThe present work was centred on the study of potassium ethylxanthate, EtX-K+, which displays a remarkable selectivity and is widely employed in the treatment of sulphide ore. It was synthesised in our laboratory and its characterisation was performed, alongside with purity assessment, by analytical assays (IR,UV) as well as by decomposition studies. In particular, we aimed to develop the polarography procedure: DC(tast) method coupled with a modern dropping mercury electrode. (SMDE) for the determination of EtX-K+, enabled us to obtain defined and reproducible anodic waves. The investigation was carried out in the presence of NaOH as a supporting electrolyte at pH 12.6 within a broad concentration range (2x10^(-6)-1x10^(-4) M). In a following stage, a flow injection analysis (FIA) system with amperometric detection with wall-jet type cells operated at -0.1 V fixed-potential was implemented. Fia-grams with reasonably reproducible peaks were generated, with a sample throughput capacity of 72 determinations/hour and detection limit is estimate in 0.16 ppm.Neste trabalho enfatizou-se o estudo do etilxantato de potássio, EtX-K+, por ser um reagente bastante seletivo e muito utilizado no tratamento de minerais sulfetados. A síntese foi feita no laboratório e a caracterizaçáo e pureza, além dos estudos de reaçoes de decomposiçáo, foram feitos com auxílio das técnicas analíticas (IR, UV). Procurou-se desenvolver a metodologia polarográfica DC(first) trabalhando com moderno eletrodo de mercúrio de gota estática (SMDE) para a determinaçáo do EtX-K+ , obtiveram-se ondas anódicas definidas e reprodutíveis, usando como eletrólito suporte NaOH, pH 12,6 e numa ampla faixa de concentracáo (2x10^(-6)- 1x10^(-4) M). Na etapa seguinte adaptou-se o método poi aro gráfico a analise por injeçáo em fluxo, FIA, com detecçáo amperométrica; trabalhando a potencial fixo de -0,1V, e usando uma célula tipo "wall-jet" feita no laboratório, foram obtidos fiagramas com picos bastante reprodutíveis; a freqüéncia da amostragem de 72 injeçoes/ hora; o limite de detecçáo foi estimado em O,16 ppm.Neste trabalho enfatizou-se o estudo do etilxantato de potássio, EtX-K+, por ser um reagente bastante seletivo e muito utilizado no tratamento de minerais sulfetados. A síntese foi feita no laboratório e a caracterizaçáo e pureza, além dos estudos de reaçoes de decomposiçáo, foram feitos com auxílio das técnicas analíticas (IR, UV). Procurou-se desenvolver a metodologia polarográfica DC(first) trabalhando com moderno eletrodo de mercúrio de gota estática (SMDE) para a determinaçáo do EtX-K+ , obtiveram-se ondas anódicas definidas e reprodutíveis, usando como eletrólito suporte NaOH, pH 12,6 e numa ampla faixa de concentracáo (2x10^(-6)- 1x10^(-4) M). Na etapa seguinte adaptou-se o método poi aro gráfico a analise por injeçáo em fluxo, FIA, com detecçáo amperométrica; trabalhando a potencial fixo de -0,1V, e usando uma célula tipo "wall-jet" feita no laboratório, foram obtidos fiagramas com picos bastante reprodutíveis; a freqüéncia da amostragem de 72 injeçoes/ hora; o limite de detecçáo foi estimado em O,16 ppm.Universidad Nacional Mayor de San Marcos1998-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4111Revista Peruana de Química e Ingeniería Química; Vol 1 No 2 (1998); 169-180Revista Peruana de Química e Ingeniería Química; Vol. 1 Núm. 2 (1998); 169-1801609-75991726-2208reponame:Revista UNMSM - Revista Peruana de Química e Ingeniería Químicainstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4111/3277Derechos de autor 1998 P. Hidalgo Fallahttp://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2021-06-01T18:10:27Zmail@mail.com - |
score |
13.887938 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).