Damage limit states for confined masonry walls based on experimental test
Descripción del Articulo
Non engineering dwellings represents 83% of the stock of housing in emerging areas of Lima city. These dwellings are build with non-appropriated masonry bricks with walls that limits don´t meet the displacement control of the earthquake design standards NTE-030 and NTE-070. Considering the database...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revista UNI - Tecnia |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/715 |
Enlace del recurso: | http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/715 |
Nivel de acceso: | acceso abierto |
id |
0375-7765_49fea6440af588e40c9d59ff3540de8b |
---|---|
oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/715 |
network_acronym_str |
0375-7765 |
repository_id_str |
. |
network_name_str |
Revista UNI - Tecnia |
spelling |
Damage limit states for confined masonry walls based on experimental testZavala, CarlosDiaz, MiguelFlores, ErikaNon engineering dwellings represents 83% of the stock of housing in emerging areas of Lima city. These dwellings are build with non-appropriated masonry bricks with walls that limits don´t meet the displacement control of the earthquake design standards NTE-030 and NTE-070. Considering the database of structural test of 33 years of experimental studies of the Structural Laboratory of CISMID, typical behavior curves are studied in order to propose damage limit state for masonry walls: build with industrial bricks, build with handmade bricks and build with horizontal hollow tubular bricks. Also, results of full-scale test on masonry house performed in the laboratory are studied. Ranges of inelastic development limit states of walls are proposed from the test results of full-scale test of the three types of masonry. Big difference in the capacity of walls with tubular bricks in comparison with the others types are found. Also limit drift values threshold are propose to be use in the analytical modelling of wall structures with handmade or tubular bricks. These proposal limits are smaller than the limit of NTE-030 standard.Non engineering dwellings represents 83% of the stock of housing in emerging areas of Lima city. These dwellings are build with non-appropriated masonry bricks with walls that limits don´t meet the displacement control of the earthquake design standards NTE-030 and NTE-070. Considering the database of structural test of 33 years of experimental studies of the Structural Laboratory of CISMID, typical behavior curves are studied in order to propose damage limit state for masonry walls: build with industrial bricks, build with handmade bricks and build with horizontal hollow tubular bricks. Also, results of full-scale test on masonry house performed in the laboratory are studied. Ranges of inelastic development limit states of walls are proposed from the test results of full-scale test of the three types of masonry. Big difference in the capacity of walls with tubular bricks in comparison with the others types are found. Also limit drift values threshold are propose to be use in the analytical modelling of wall structures with handmade or tubular bricks. These proposal limits are smaller than the limit of NTE-030 standard.Universidad Nacional de Ingeniería2019-08-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionTECNIA Special Issue on Earthquake Engineeringapplication/pdfaudio/mpeghttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/71510.21754/tecnia.v29i2.715TECNIA; Vol 29 No 2 (2019): Special Issue on Earthquake EngineeringTECNIA; Vol. 29 Núm. 2 (2019): Edición especial en Ingeniería Sísmica2309-04130375-7765reponame:Revista UNI - Tecniainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttp://www.revistas.uni.edu.pe/index.php/tecnia/article/view/715/1114http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/715/1132info:eu-repo/semantics/openAccess2021-05-29T15:55:42Zmail@mail.com - |
dc.title.none.fl_str_mv |
Damage limit states for confined masonry walls based on experimental test |
title |
Damage limit states for confined masonry walls based on experimental test |
spellingShingle |
Damage limit states for confined masonry walls based on experimental test Zavala, Carlos |
title_short |
Damage limit states for confined masonry walls based on experimental test |
title_full |
Damage limit states for confined masonry walls based on experimental test |
title_fullStr |
Damage limit states for confined masonry walls based on experimental test |
title_full_unstemmed |
Damage limit states for confined masonry walls based on experimental test |
title_sort |
Damage limit states for confined masonry walls based on experimental test |
dc.creator.none.fl_str_mv |
Zavala, Carlos Diaz, Miguel Flores, Erika |
author |
Zavala, Carlos |
author_facet |
Zavala, Carlos Diaz, Miguel Flores, Erika |
author_role |
author |
author2 |
Diaz, Miguel Flores, Erika |
author2_role |
author author |
dc.description.none.fl_txt_mv |
Non engineering dwellings represents 83% of the stock of housing in emerging areas of Lima city. These dwellings are build with non-appropriated masonry bricks with walls that limits don´t meet the displacement control of the earthquake design standards NTE-030 and NTE-070. Considering the database of structural test of 33 years of experimental studies of the Structural Laboratory of CISMID, typical behavior curves are studied in order to propose damage limit state for masonry walls: build with industrial bricks, build with handmade bricks and build with horizontal hollow tubular bricks. Also, results of full-scale test on masonry house performed in the laboratory are studied. Ranges of inelastic development limit states of walls are proposed from the test results of full-scale test of the three types of masonry. Big difference in the capacity of walls with tubular bricks in comparison with the others types are found. Also limit drift values threshold are propose to be use in the analytical modelling of wall structures with handmade or tubular bricks. These proposal limits are smaller than the limit of NTE-030 standard. Non engineering dwellings represents 83% of the stock of housing in emerging areas of Lima city. These dwellings are build with non-appropriated masonry bricks with walls that limits don´t meet the displacement control of the earthquake design standards NTE-030 and NTE-070. Considering the database of structural test of 33 years of experimental studies of the Structural Laboratory of CISMID, typical behavior curves are studied in order to propose damage limit state for masonry walls: build with industrial bricks, build with handmade bricks and build with horizontal hollow tubular bricks. Also, results of full-scale test on masonry house performed in the laboratory are studied. Ranges of inelastic development limit states of walls are proposed from the test results of full-scale test of the three types of masonry. Big difference in the capacity of walls with tubular bricks in comparison with the others types are found. Also limit drift values threshold are propose to be use in the analytical modelling of wall structures with handmade or tubular bricks. These proposal limits are smaller than the limit of NTE-030 standard. |
description |
Non engineering dwellings represents 83% of the stock of housing in emerging areas of Lima city. These dwellings are build with non-appropriated masonry bricks with walls that limits don´t meet the displacement control of the earthquake design standards NTE-030 and NTE-070. Considering the database of structural test of 33 years of experimental studies of the Structural Laboratory of CISMID, typical behavior curves are studied in order to propose damage limit state for masonry walls: build with industrial bricks, build with handmade bricks and build with horizontal hollow tubular bricks. Also, results of full-scale test on masonry house performed in the laboratory are studied. Ranges of inelastic development limit states of walls are proposed from the test results of full-scale test of the three types of masonry. Big difference in the capacity of walls with tubular bricks in comparison with the others types are found. Also limit drift values threshold are propose to be use in the analytical modelling of wall structures with handmade or tubular bricks. These proposal limits are smaller than the limit of NTE-030 standard. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-08-12 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion TECNIA Special Issue on Earthquake Engineering |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/715 10.21754/tecnia.v29i2.715 |
url |
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/715 |
identifier_str_mv |
10.21754/tecnia.v29i2.715 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/715/1114 http://www.revistas.uni.edu.pe/index.php/tecnia/article/view/715/1132 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf audio/mpeg |
dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
dc.source.none.fl_str_mv |
TECNIA; Vol 29 No 2 (2019): Special Issue on Earthquake Engineering TECNIA; Vol. 29 Núm. 2 (2019): Edición especial en Ingeniería Sísmica 2309-0413 0375-7765 reponame:Revista UNI - Tecnia instname:Universidad Nacional de Ingeniería instacron:UNI |
reponame_str |
Revista UNI - Tecnia |
collection |
Revista UNI - Tecnia |
instname_str |
Universidad Nacional de Ingeniería |
instacron_str |
UNI |
institution |
UNI |
repository.name.fl_str_mv |
-
|
repository.mail.fl_str_mv |
mail@mail.com |
_version_ |
1701108800463831040 |
score |
13.887938 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).