Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén

Descripción del Articulo

The country has a lot of effluents from treatment plants or Municipal Wastewater (WWTP) that are discharged into natural water bodies, affecting their quality. As of April 1, 2009 carne into force No. 29338, Law on Water Resources Act, which states that the National Water Authority is responsible fo...

Descripción completa

Detalles Bibliográficos
Autor: Raccbumí Linares, Karem Cbristy Giuliana
Formato: tesis de grado
Fecha de Publicación:2016
Institución:Universidad Nacional de San Martin - Tarapoto
Repositorio:UNSM-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unsm.edu.pe:11458/224
Enlace del recurso:http://hdl.handle.net/11458/224
Nivel de acceso:acceso abierto
Materia:Determinación
grado
eficiencia
planta
tratamiento
aguas
residuales
domésticas
localidad
Segunda
Jerusalén
id UNSM_70c9f398e88a5d048018ac58adc2a6a0
oai_identifier_str oai:repositorio.unsm.edu.pe:11458/224
network_acronym_str UNSM
network_name_str UNSM-Institucional
repository_id_str
dc.title.es_PE.fl_str_mv Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
title Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
spellingShingle Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
Raccbumí Linares, Karem Cbristy Giuliana
Determinación
grado
eficiencia
planta
tratamiento
aguas
residuales
domésticas
localidad
Segunda
Jerusalén
title_short Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
title_full Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
title_fullStr Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
title_full_unstemmed Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
title_sort Determinación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusalén
author Raccbumí Linares, Karem Cbristy Giuliana
author_facet Raccbumí Linares, Karem Cbristy Giuliana
author_role author
dc.contributor.advisor.fl_str_mv Rojas Vásquez, Juan Carlos
dc.contributor.author.fl_str_mv Raccbumí Linares, Karem Cbristy Giuliana
dc.subject.es_PE.fl_str_mv Determinación
grado
eficiencia
planta
tratamiento
aguas
residuales
domésticas
localidad
Segunda
Jerusalén
topic Determinación
grado
eficiencia
planta
tratamiento
aguas
residuales
domésticas
localidad
Segunda
Jerusalén
description The country has a lot of effluents from treatment plants or Municipal Wastewater (WWTP) that are discharged into natural water bodies, affecting their quality. As of April 1, 2009 carne into force No. 29338, Law on Water Resources Act, which states that the National Water Authority is responsible for the protection of water as a water resource. In this sense, controls, supervises and monitors compliance with water quality standards based on the National Environmental Quality Standards for Water (ECA-Water). In that sense, this project sought to determine the efficiency of the treatment plant domestic wastewater in the city of Jerusalem Second- Rioja 2014. The parameters subject to monitoring WWTP effluents were as shown in S.D. No. 003- 2010-MINAM for which the maximum permissible limits are fixed. These are: Oils and Fats, thermotolerant coliforms, biochemical oxygen demand, chemical oxygen demand, pH, total suspended solids and temperature. These parameters were monitored in the raw wastewater (influent) and treated wastewater (effiuent), taking in all cases single samples. The parameters had higher levels of efficiency in descending order were the Thermotolerant Coliform with 94.63%, total suspended solids with 86.52%, chemical oxygen demand with 76.65%, with 75.09 Oils and Fats, biological oxygen demand with 75.06%, pH 1.05% with respectto temperature with -2.89%, the negative value is a result there is a decrease between the influent and effiuent. The values of thermotolerant coliforms, COD, BOD 5 and PH, reported values obtained regardless of the degree of efficiency, the values do not meet the maximum permissible limits established in the DS N o 003-2008- MINAM situation possibly influenced by production DB05 residual due to the decomposition of waste water plants and other natural organic matter present in the lagoons. The treatment system achieving good efficiency in the removal of oils and fats, presented a value of 75.09%, indicating that according to the limits for the control of discharges S.D. No. 003-2008-MINAM complies with the requirements
publishDate 2016
dc.date.accessioned.none.fl_str_mv 2016-11-02T19:04:30Z
dc.date.available.none.fl_str_mv 2016-11-02T19:04:30Z
dc.date.issued.fl_str_mv 2016
dc.type.en_US.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.citation.es_PE.fl_str_mv Apa
dc.identifier.other.none.fl_str_mv 6053214
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/11458/224
identifier_str_mv Apa
6053214
url http://hdl.handle.net/11458/224
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.en_US.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Universidad Nacional de San Martín
dc.source.es_PE.fl_str_mv Universidad Nacional de San Martín
Repositorio de Tesis – UNSM
dc.source.none.fl_str_mv reponame:UNSM-Institucional
instname:Universidad Nacional de San Martin - Tarapoto
instacron:UNSM
instname_str Universidad Nacional de San Martin - Tarapoto
instacron_str UNSM
institution UNSM
reponame_str UNSM-Institucional
collection UNSM-Institucional
bitstream.url.fl_str_mv http://repositorio.unsm.edu.pe/bitstream/11458/224/3/6053214.pdf.jpg
http://repositorio.unsm.edu.pe/bitstream/11458/224/1/6053214.pdf
http://repositorio.unsm.edu.pe/bitstream/11458/224/2/6053214.pdf.txt
bitstream.checksum.fl_str_mv 89d477f650e3e3ee264ce9361e121c6a
566e16209b64959f754545bc58ce925f
dd3c238934a0c87cf58a255dc005120a
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional de la Universidad
repository.mail.fl_str_mv repositorio@unsm.edu.pe
_version_ 1741962178841280512
spelling Rojas Vásquez, Juan Carlos4ec689ae-3dee-44ac-b263-6391d8389f70Raccbumí Linares, Karem Cbristy Giuliana2016-11-02T19:04:30Z2016-11-02T19:04:30Z2016Apa6053214http://hdl.handle.net/11458/224The country has a lot of effluents from treatment plants or Municipal Wastewater (WWTP) that are discharged into natural water bodies, affecting their quality. As of April 1, 2009 carne into force No. 29338, Law on Water Resources Act, which states that the National Water Authority is responsible for the protection of water as a water resource. In this sense, controls, supervises and monitors compliance with water quality standards based on the National Environmental Quality Standards for Water (ECA-Water). In that sense, this project sought to determine the efficiency of the treatment plant domestic wastewater in the city of Jerusalem Second- Rioja 2014. The parameters subject to monitoring WWTP effluents were as shown in S.D. No. 003- 2010-MINAM for which the maximum permissible limits are fixed. These are: Oils and Fats, thermotolerant coliforms, biochemical oxygen demand, chemical oxygen demand, pH, total suspended solids and temperature. These parameters were monitored in the raw wastewater (influent) and treated wastewater (effiuent), taking in all cases single samples. The parameters had higher levels of efficiency in descending order were the Thermotolerant Coliform with 94.63%, total suspended solids with 86.52%, chemical oxygen demand with 76.65%, with 75.09 Oils and Fats, biological oxygen demand with 75.06%, pH 1.05% with respectto temperature with -2.89%, the negative value is a result there is a decrease between the influent and effiuent. The values of thermotolerant coliforms, COD, BOD 5 and PH, reported values obtained regardless of the degree of efficiency, the values do not meet the maximum permissible limits established in the DS N o 003-2008- MINAM situation possibly influenced by production DB05 residual due to the decomposition of waste water plants and other natural organic matter present in the lagoons. The treatment system achieving good efficiency in the removal of oils and fats, presented a value of 75.09%, indicating that according to the limits for the control of discharges S.D. No. 003-2008-MINAM complies with the requirementsEn el país existe una gran cantidad de efluentes provenientes de las Plantas de Tratamiento de Aguas Residuales Domésticas o Municipales (PT AR) que son vertidos a los cuerpos naturales de agua, afectando la calidad de los mismos. A partir del O 1 de abril del2009 entró en vigencia la Ley N° 29338, Ley de Recursos Hídricos, que establece que la Autoridad Nacional del Agua es la responsable de la protección del agua como recurso hídrico. En este sentido, controla, supervisa y fiscaliza el cumplimiento de las normas de calidad del agua sobre la base de los Estándares Nacionales de Calidad Ambiental para el Agua (ECA-Agua). En ese sentido el presente proyecto busco determinar el grado de eficiencia de la planta de tratamiento de aguas residuales domesticas en la localidad de Segunda Jerusalén- Rioja 2014. Los parámetros sujetos al monitoreo de los efluentes de las PT AR fueron los indicados en el D.S. N° 003-2010-MINAM para los cuales se fija los Límites Máximos Permisibles. Estos son los siguientes: Aceites y Grasas, Coliformes Termotolerantes, Demanda Bioquímica de Oxígeno, Demanda Química de Oxígeno, pH, Sólidos Totales Suspendidos y Temperatura. Estos parámetros se monitorearon en el agua residual cruda (afluente) y en el agua residual tratada (efluente), tomando en todos los casos muestras simples. Los parámetros que presentaron mayores niveles de eficiencia en orden decreciente fueron los Coliformes Termotolerantes con 94.63%, Solidos Suspendidos Totales con 86.52%, Demanda Química de Oxigeno con 76.65%, Aceites y Grasas con 75.09, Demanda Biológica de Oxigeno con 75.06%, Ph con 1.05% y con respecto a la temperatura con -2.89%, cuyo valor negativo es a consecuencia hay un descenso entre el afluente y efluente. Los valores de Coliformes Termotolerantes, DQO, DB05 y PH, reportan valores que independientemente del grado de eficiencia obtenido, los valores no cumplen con los Límites Máximos Permisibles establecidos en el D.S N° 003-2008- MINAM, situación posiblemente influida por la producción de DB05 residual debida a la descomposición de los residuos de plantas acuáticas y otra materia orgánica natural presente en las lagunas. El sistema de tratamiento logro buena eficiencia en la remoción de aceites y grasas, presentado un valor de 75.09% e indica que de acuerdo a los limites exigidos para el control de vertimientos D.S. N° 003-2008-MINAM, cumple con lo estipulado.Tesisapplication/pdfspaUniversidad Nacional de San Martíninfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de San MartínRepositorio de Tesis – UNSMreponame:UNSM-Institucionalinstname:Universidad Nacional de San Martin - Tarapotoinstacron:UNSMDeterminacióngradoeficienciaplantatratamientoaguasresidualesdomésticaslocalidadSegundaJerusalénDeterminación del grado de eficiencia de la planta de tratamiento de aguas residuales domésticas en la localidad de Segunda Jerusaléninfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalIngenieria AmbientalUniversidad Nacional de San Martín.Facultad de EcologíaIngeniero AmbientalTHUMBNAIL6053214.pdf.jpg6053214.pdf.jpgGenerated Thumbnailimage/jpeg959http://repositorio.unsm.edu.pe/bitstream/11458/224/3/6053214.pdf.jpg89d477f650e3e3ee264ce9361e121c6aMD53ORIGINAL6053214.pdfapplication/pdf1718716http://repositorio.unsm.edu.pe/bitstream/11458/224/1/6053214.pdf566e16209b64959f754545bc58ce925fMD51TEXT6053214.pdf.txt6053214.pdf.txtExtracted texttext/plain72699http://repositorio.unsm.edu.pe/bitstream/11458/224/2/6053214.pdf.txtdd3c238934a0c87cf58a255dc005120aMD5211458/224oai:repositorio.unsm.edu.pe:11458/2242021-12-22 03:07:06.498Repositorio Institucional de la Universidadrepositorio@unsm.edu.pe
score 13.856838
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).