Numerical simulation of velocity field in a arteriouvenous fístula

Descripción del Articulo

The objective of this study is to analyze the hemodynamic factors of flow in an arteriovenous fistula (AVF). The geometric model of the AVF is obtained virtually from a computed tomography. In the mathematical model, which simulates blood flow in the AVF, it is considered a non-Newtonian fluid, inco...

Descripción completa

Detalles Bibliográficos
Autores: A. Santos, Willyam B., M. Borjas, Santos D., C. Moreira, Ricardo W., L. Bessa, Kleiber
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Nacional de Trujillo
Repositorio:Revista UNITRU - Selecciones Matemáticas
Lenguaje:español
OAI Identifier:oai:ojs.revistas.unitru.edu.pe:article/2452
Enlace del recurso:http://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452
Nivel de acceso:acceso abierto
Materia:Arteriovenous fistula
Velocity field
CFD
Fístula Arteriovesa
Campo de Velocidade
DFC
id 2306-6741_c4e5b90f328f7de06361bc43b68bf7a2
oai_identifier_str oai:ojs.revistas.unitru.edu.pe:article/2452
network_acronym_str 2306-6741
network_name_str Revista UNITRU - Selecciones Matemáticas
spelling Numerical simulation of velocity field in a arteriouvenous fístulaSimulacao numérica do campo de velocidade em fístula arteriovenosaA. Santos, Willyam B.M. Borjas, Santos D.C. Moreira, Ricardo W.L. Bessa, KleiberArteriovenous fistulaVelocity fieldCFDFístula ArteriovesaCampo de VelocidadeDFCThe objective of this study is to analyze the hemodynamic factors of flow in an arteriovenous fistula (AVF). The geometric model of the AVF is obtained virtually from a computed tomography. In the mathematical model, which simulates blood flow in the AVF, it is considered a non-Newtonian fluid, incompressible and transient laminar flow. The flow behavior in the AVF is given by the blood velocity in five points corresponding to the mass flow in the systolic phase and in the diastolic phase. The numerical simulation of the velocity field in the systolic phasepresented greater intensity of axial and radial recirculations. The presence of recirculations allows figurative elements to collide excessively in the wall of the endotheliumO objetivo deste trabalho e analisar os fatores hemodinamicos do escoamento numa fístula arteriovenosa (FAV). O modelo geométrico da FAV é obtido virtualmente a partir de uma tomografia computadorizada. No modelo matemático, que simula o fluxo da sangue na FAV, é considerado um fluido nao-Newtoniano, escoamento laminar, incompressível e em regime transiente. O comportamento do fluxo na FAV é dado pela velocidade do sangue em cinco pontos correspondente á vazao mássica em fase sistólica e em fase diastólica. A simulacao numérica do campo de velocidade na fase sistólica apresentou maior intensidade de recirculacoes axiais e radiais. A presenca de recirculacoes permite que elementos figurados se choquem excessivamente na parede do endotélio.National University of Trujillo - Academic Department of Mathematics2019-07-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlhttp://revistas.unitru.edu.pe/index.php/SSMM/article/view/245210.17268/sel.mat.2019.01.12Selecciones Matemáticas; Vol. 6 Núm. 01 (2019): Enero-Julio; 98-107Selecciones Matemáticas; Vol. 6 No. 01 (2019): Enero-Julio; 98-107Selecciones Matemáticas; v. 6 n. 01 (2019): Enero-Julio; 98-1072411-1783reponame:Revista UNITRU - Selecciones Matemáticasinstname:Universidad Nacional de Trujilloinstacron:UNITRUspahttp://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2487http://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2504Derechos de autor 2019 Selecciones Matemáticasinfo:eu-repo/semantics/openAccess2021-03-03T15:25:18Zmail@mail.com -
dc.title.none.fl_str_mv Numerical simulation of velocity field in a arteriouvenous fístula
Simulacao numérica do campo de velocidade em fístula arteriovenosa
title Numerical simulation of velocity field in a arteriouvenous fístula
spellingShingle Numerical simulation of velocity field in a arteriouvenous fístula
A. Santos, Willyam B.
Arteriovenous fistula
Velocity field
CFD
Fístula Arteriovesa
Campo de Velocidade
DFC
title_short Numerical simulation of velocity field in a arteriouvenous fístula
title_full Numerical simulation of velocity field in a arteriouvenous fístula
title_fullStr Numerical simulation of velocity field in a arteriouvenous fístula
title_full_unstemmed Numerical simulation of velocity field in a arteriouvenous fístula
title_sort Numerical simulation of velocity field in a arteriouvenous fístula
dc.creator.none.fl_str_mv A. Santos, Willyam B.
M. Borjas, Santos D.
C. Moreira, Ricardo W.
L. Bessa, Kleiber
author A. Santos, Willyam B.
author_facet A. Santos, Willyam B.
M. Borjas, Santos D.
C. Moreira, Ricardo W.
L. Bessa, Kleiber
author_role author
author2 M. Borjas, Santos D.
C. Moreira, Ricardo W.
L. Bessa, Kleiber
author2_role author
author
author
dc.subject.none.fl_str_mv Arteriovenous fistula
Velocity field
CFD
Fístula Arteriovesa
Campo de Velocidade
DFC
topic Arteriovenous fistula
Velocity field
CFD
Fístula Arteriovesa
Campo de Velocidade
DFC
dc.description.none.fl_txt_mv The objective of this study is to analyze the hemodynamic factors of flow in an arteriovenous fistula (AVF). The geometric model of the AVF is obtained virtually from a computed tomography. In the mathematical model, which simulates blood flow in the AVF, it is considered a non-Newtonian fluid, incompressible and transient laminar flow. The flow behavior in the AVF is given by the blood velocity in five points corresponding to the mass flow in the systolic phase and in the diastolic phase. The numerical simulation of the velocity field in the systolic phasepresented greater intensity of axial and radial recirculations. The presence of recirculations allows figurative elements to collide excessively in the wall of the endothelium
O objetivo deste trabalho e analisar os fatores hemodinamicos do escoamento numa fístula arteriovenosa (FAV). O modelo geométrico da FAV é obtido virtualmente a partir de uma tomografia computadorizada. No modelo matemático, que simula o fluxo da sangue na FAV, é considerado um fluido nao-Newtoniano, escoamento laminar, incompressível e em regime transiente. O comportamento do fluxo na FAV é dado pela velocidade do sangue em cinco pontos correspondente á vazao mássica em fase sistólica e em fase diastólica. A simulacao numérica do campo de velocidade na fase sistólica apresentou maior intensidade de recirculacoes axiais e radiais. A presenca de recirculacoes permite que elementos figurados se choquem excessivamente na parede do endotélio.
description The objective of this study is to analyze the hemodynamic factors of flow in an arteriovenous fistula (AVF). The geometric model of the AVF is obtained virtually from a computed tomography. In the mathematical model, which simulates blood flow in the AVF, it is considered a non-Newtonian fluid, incompressible and transient laminar flow. The flow behavior in the AVF is given by the blood velocity in five points corresponding to the mass flow in the systolic phase and in the diastolic phase. The numerical simulation of the velocity field in the systolic phasepresented greater intensity of axial and radial recirculations. The presence of recirculations allows figurative elements to collide excessively in the wall of the endothelium
publishDate 2019
dc.date.none.fl_str_mv 2019-07-21
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452
10.17268/sel.mat.2019.01.12
url http://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452
identifier_str_mv 10.17268/sel.mat.2019.01.12
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2487
http://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2504
dc.rights.none.fl_str_mv Derechos de autor 2019 Selecciones Matemáticas
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2019 Selecciones Matemáticas
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
text/html
dc.publisher.none.fl_str_mv National University of Trujillo - Academic Department of Mathematics
publisher.none.fl_str_mv National University of Trujillo - Academic Department of Mathematics
dc.source.none.fl_str_mv Selecciones Matemáticas; Vol. 6 Núm. 01 (2019): Enero-Julio; 98-107
Selecciones Matemáticas; Vol. 6 No. 01 (2019): Enero-Julio; 98-107
Selecciones Matemáticas; v. 6 n. 01 (2019): Enero-Julio; 98-107
2411-1783
reponame:Revista UNITRU - Selecciones Matemáticas
instname:Universidad Nacional de Trujillo
instacron:UNITRU
reponame_str Revista UNITRU - Selecciones Matemáticas
collection Revista UNITRU - Selecciones Matemáticas
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1693224944335323136
score 13.919034
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).